From the paper's conclusion- Due to the optical diffraction limit (~200 nm), fluorescence microscopy captures the spatial overlap of these two QD signals, which appears as yellow spots and serves as a distinct marker for heparin detection at the single-nanoparticle level.
Abstract
In this paper, we present a sensitive single-nanoparticle counting method for heparin detection, which integrates single-nanoparticle fluorescence imaging with dual-color quantum dot (QD) labeling. This approach enables heparin quantification by analyzing the combined red and green fluorescence signals from two specially modified QDs, allowing for the precise quantification of heparin concentration in a sample. Due to the optical diffraction limit (~200 nm), fluorescence microscopy captures the spatial overlap of these two QD signals, which appears as yellow spots and serves as a distinct marker for heparin detection at the single-nanoparticle level. Heparin concentration shows a linear correlation with the aggregation ratio of dual-color QDs over the range of 0.001 to 0.02 U/mL, with a detection limit as low as 5.4 × 10−4 U/mL. Additionally, successful recovery tests in serum validate the accuracy and reliability of this method for potential clinical applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensitive Fluorescent Detection of Heparin and Protamine Using a Propidium Iodide-Based Sensing System.Luminescence : the journal of biological and chemical luminescence · 2026
- Emissive nanoaggregate-based dual sensing of heparin and protamine sulphate.Analytical methods : advancing methods and applications · 2026
- An Eco-Friendly N-Doped Carbon Quantum Dot-Based Fluorimetric Assay for Sensitive Betahistine Quantitation in Pharmaceuticals and Biological Fluids.Luminescence : the journal of biological and chemical luminescence · 2026
- A highly sensitive carbon quantum dots sensor for hypochlorite ion detection through fluorescence-off method.RSC advances · 2026
- A Hyperbranched Rolling Circle Amplification Assay Using Aptamer-Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB.ACS measurement science au · 2026
- Smartphone‐Assisted Visual and Fluorometric Detection of Meloxicam Using Fluorescent Carbon Quantum Dots With Greenness AssessmentChemistrySelect · 2026