Wearable Biomechanical Sensing Platform Integrated on Rigid-Flexible Coupled Load-Bearing Exoskeleton: Multi-Terrain Human-Machine Force Monitoring and Physiological Metabolic Validation.
Yongtang Tian, Chunjie Chen, Wujing Cao, Xiaojun Wu, Xinyu Wu
School of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China. · Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Key points
From the paper's conclusion- A descriptive gradual decline in metabolic saving was observed, likely attributable to terrain perturbations, gait distortion, and human–machine interface slippage, with metabolic cost reductions of 16.28%, 11.93%, and 11.48%.
Abstract
Multi-terrain adaptability and metabolic reduction are critical for translating load-carrying lower-limb exoskeletons into practical use. However, conventional single-mode sensing cannot synchronously quantify human-exoskeleton interaction forces and physiological metabolic responses across complex terrains. To address this limitation, this study develops a rigid-flexible coupled load-carrying lower-limb exoskeleton and constructs a dual-modal test platform for interaction force and metabolic energy expenditure. Using DYMH-102 diaphragm box load cells and the Cosmed K5 portable gas metabolism analyzer, a standardized outdoor multi-scenario sensing protocol is established. This protocol quantifies exoskeleton assistance performance and human metabolic benefits under a 15 kg load over three representative terrains: hard level ground (HLG), gently uneven grassland (GUG), and gently sloped mountain road (GMR). The experimental results show that terrain complexity directly affects sensor measurement outcomes and exoskeleton assistance performance: under the three terrain conditions, the shoulder load transfer efficiencies of the exoskeleton are 55.97%, 54.76%, and 42.45%, respectively, and the peak impact load reduction rates reach 78.26%, 80.00%, and 66.67%. A descriptive gradual decline in metabolic saving was observed, likely attributable to terrain perturbations, gait distortion, and human-machine interface slippage, with metabolic cost reductions of 16.28%, 11.93%, and 11.48%. Unlike conventional exoskeleton evaluations relying on isolated performance metrics, this work integrates mechanical and physiological dual-modal sensing to create a synchronous quantitative assessment method for wearable devices in complex outdoor environments. The proposed method mitigates the poor terrain adaptability and lack of multi-parameter coupled evaluation that plague current wearable biosensing systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Performance Evaluation of Unpowered Hip-Assisted Exoskeletons.Biomimetics (Basel, Switzerland) · 2026
- Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors.Biomimetics (Basel, Switzerland) · 2026
- Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance StrategiesarXiv · 2026
- Biosensor-Monitored Metabolic Effects of Asymmetric Bilateral Hip-Exoskeleton Assistance in Individuals with Transfemoral AmputationBiosensors · 2026
- In-Field IMU-Based Monitoring of Running-Specific Prostheses and Athlete Movement During Long-Distance Running: A Case StudyApplied Sciences · 2026
- Benchmarking the predictive capability of human gait simulationsPLoS Computational Biology · 2025