Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors.
Saikat Sahoo, Yoosun Kim, Dongmin Go, Sejun Park, Jeongho Choo, Gyeongmo Kim, Cheonkyu Park, Giuk Lee
Department of Mechanical Engineering, Chung-Ang University, Seoul 06974, Republic of Korea.
Key points
From the paper's conclusion- The MVCF, computed solely from onboard sensors, served as the objective of Bayesian HITL optimization in five participants.
Abstract
Human-in-the-loop (HITL) optimization can personalize exosuit assistance, but respirometry-based cost functions require bulky equipment, and proxy-based alternatives often require additional sensors or leave their relationship with metabolism unquantified. Our previous onboard-sensor approach optimized a single objective based on positive mechanical power (PMP). This exploratory study investigated whether stride time (ST), a gait response measured by the exosuit's thigh-mounted inertial sensors, better represents metabolic reduction. Using grid-search data from three participants walking at 1 m/s on a 5° incline with a hip extension exosuit (six subject-day cases), we evaluated PMP, ST, and their combination by multiple linear regression, termed the multi-variable cost function (MVCF), with leave-one-subject-out cross-validation. ST predicted metabolic reduction numerically better than PMP (r = 0.63 ± 0.14 vs. 0.51 ± 0.37), and the MVCF performed best (r = 0.68 ± 0.11; lowest mean absolute error), although no difference was statistically significant. The MVCF, computed solely from onboard sensors, served as the objective of Bayesian HITL optimization in five participants. The optimized assistance significantly reduced net metabolic rate by 13.3%, 7.5%, and 5.2% versus power-off, no-suit, and biomimetic conditions, respectively. Combining device-side mechanical power with human-side gait timing may provide an onboard-sensor cost function grounded in measured metabolic data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- User preference-based human-in-the-loop tuning of exoskeleton assistance during walkingnpj Biomedical Innovations. · 2026
- Multi-Agent Reinforcement Learning of Co-Adaptive Hip Exoskeleton Control (MARL-Exo) for Metabolic Energy ReductionarXiv · 2026
- A Gait-Conditioned Human-in-the-Loop Optimization Framework Based on Gait-Assistance-Response Relationship Model for Exoskeleton Assistance.Bioengineering (Basel, Switzerland) · 2026
- EMG-Based Simulation for Optimization of Human-in-the-Loop Control in Simple Robotic Walking Assistance.Journal of sensor and actuator networks · 2025
- Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance StrategiesarXiv · 2026
- PositiveAssist: Energy-Gated Control for Positive Power Assistance of Exoskeleton in Walking, Running, and Stair Climbing.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2026