Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation.
Ceyhun E Kırımlı, Elçim Elgün, Selin Yağmur Tuğtağ
Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türkiye. · Department of Biomedical Engineering, Graduate School of Natural and Applied Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türkiye.
Key points
From the paper's conclusion- Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing.
Abstract
Liquid-phase quartz crystal microbalance (QCM) biosensors are commonly quantified using scalar readouts such as frequency shift, dissipation, or bandwidth. Although useful, these descriptors discard resonance line-shape morphology that carries additional information for quantitative inference. Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing. A passive microfluidic mixer generated controlled glycerol-water concentration gradients under constant total flow while complex impedance spectra were acquired in real time, and each sweep was parameterized using constrained Gaussian/Lorentzian models to obtain 52 physically interpretable descriptors spanning resistance, reactance, impedance magnitude, admittance components, and phase. The pipeline combines consensus outlier handling, training-fold mRMR feature ranking, and regression models evaluated under both shuffled five-fold cross-validation and a stricter temporally blocked protocol in which contiguous portions of the experiment are held out. The workflow achieved R2=0.948 under shuffled validation and R2=0.823 under seven-block temporal validation, the latter reducing prediction error by 48.4% relative to a row-matched Kanazawa frequency-shift baseline evaluated on the same sweeps. Feature-set ablation indicated that phase and conductance line-shape descriptors carry particularly strong temporally generalizable information. Applied to an experimental DNA hybridization assay in 1× PBS, the workflow reduced mean absolute percentage concentration error from 21.02% to 10.73%, a 48.9% improvement over conventional Δf calibration. Retaining resonance morphology therefore improves quantitative QCM biosensing beyond scalar frequency-shift calibration and provides an interpretable basis for AI-assisted electronic biosensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quartz crystal microbalance biosensors for clinical biomarker detection: Advances in biorecognition, immobilization, and signal enhancement strategies.Biosensors & bioelectronics · 2026
- Precise detection of single particles and bio-sensing applications on quartz crystal microbalance using non-linear resonance behaviorMicrosystems & Nanoengineering · 2026
- Characterizing Variations in Binding Kinetics of Affinity Biosensors: A Boundary-Layer and Site-Quality Approach.ACS omega · 2026
- Analysis of compressional acoustic wave responses in cell culture media for reliable QCM-based breast cancer cell monitoringFrontiers in Sensors · 2026
- Quartz-on-Silicon Microacoustic Multiplexed Biosensor for In Vitro Label-Free Medical Diagnosis.ACS sensors · 2026
- Opto-acoustic sensor for protein conformational fingerprinting beyond concentration degeneracy: analytical modelling and AI-based sorting.Optics express · 2026