Quartz-on-Silicon Microacoustic Multiplexed Biosensor for In Vitro Label-Free Medical Diagnosis.
Aleksander Oseev, Franck Chollet, Thomas Lecompte, Thérèse Leblois
Université Marie et Louis Pasteur, CNRS, FEMTO-ST Institute, F25000Besançon, France. · Université de Lorraine, F54000Nancy, France.
Key points
From the paper's conclusion- We have then characterized the specificity, repeatability, cross-talk, and sensitivity and estimated the resolution of the multiplexed biosensor.
Abstract
Advanced biomedical analyses require simultaneous quantification of multiple entities (cells, proteins, viruses, vesicles, …) calling for a multiplexed and compact biosensor. Label-free approaches giving access to the kinetic of interaction between key molecules are solid candidates for these analyses, but they currently lack either robustness for field use, multiplexing ability, or specificity. In this contribution, we report on the development of a new type of device that merges advantages of microsystem-based integrated solutions and performance of quartz acoustic wave biosensors. We have fabricated an acoustic wave biosensor composed of multiple independent detection units, each equipped with a specific surface biointerface for the selective detection and quantification of target analytes. The implementation of reflector structures on each sensing unit enables effective wave confinement, allowing for multiplexed measurements without compromising the performance of individual units. This technology relies on commercially available quartz and silicon wafers. To demonstrate the usefulness of our approach, we developed a proof-of-concept biosensor for the assessment of primary hemostasis. This assessment is based on monitoring the adhesion of platelets on functionalized surfaces during the sequence of events that leads to primary hemostasis. The biosensor directly takes whole blood and allows real-time measurement of resonance frequency and dissipation factor of 3 sensing units placed in a row. We have then characterized the specificity, repeatability, cross-talk, and sensitivity and estimated the resolution of the multiplexed biosensor. Finally, the device allowed detecting a simulated primary hemostasis defect using a modified blood sample. This proposed bioassay technology offers strong potential for broad applications in biomedical studies as an improved alternative to quartz crystal microbalance-based devices for multiplexed biointeraction analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Precise detection of single particles and bio-sensing applications on quartz crystal microbalance using non-linear resonance behaviorMicrosystems & Nanoengineering · 2026
- Quartz crystal microbalance biosensors for clinical biomarker detection: Advances in biorecognition, immobilization, and signal enhancement strategies.Biosensors & bioelectronics · 2026
- Multiplex Detection in Label-Free Optical Biosensors: A Comparative Review of Seven PlatformsMicromachines · 2026
- Microfluidic impedance cytometry chip combining composite cell pre-focusing microchannel and 3D symmetric microelectrodes for cell classificationBiomicrofluidics · 2026
- Label-free biomolecular sensing via near-interface single-particle Brownian motion tracking.Biosensors & bioelectronics · 2026
- Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation.Biosensors · 2026