Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8).
Rigoberto Tovar, Sarkis Sozkes, Marzhan Sypabekova
Department of Bioengineering, Civil Engineering, and Environmental Engineering, U. A. Whitaker College of Engineering, Florida Gulf Coast University, 10501 FGCU Boulevard South, Fort Myers, FL 33965, USA.
Key points
From the paper's conclusion- A miniature label-free biosensor based on a chemically etched single-mode optical fiber (SMF) is reported for the detection of matrix metalloproteinase-8 (MMP-8), a salivary biomarker of active periodontitis with a clinical decision threshold of 20 ng/mL.
Abstract
A miniature label-free biosensor based on a chemically etched single-mode optical fiber (SMF) is reported for the detection of matrix metalloproteinase-8 (MMP-8), a salivary biomarker of active periodontitis with a clinical decision threshold of 20 ng/mL. Fibers etched in 48% hydrofluoric acid to a waist diameter of 16.0 ± 1.4 µm gave a mean refractive index (RI) sensitivity of 376.8%/RIU and an RI limit of detection (LOD) of 5.9 × 10-4 RIU. Fibers were tested with MMP-8 spiked into phosphate-buffered saline (PBS) and into saliva over 0-200 ng/mL using a post-rinse protocol with per-fiber matrix subtraction. Dose-responses followed a Langmuir isotherm (Kd = 7.1 ng/mL in PBS, 12.7 ng/mL in saliva), with cohort LODs of 0.043 and 0.52 ng/mL, both well below the threshold. MMP-9 (100 ng/mL) and human serum albumin (1 mg/mL) gave negligible responses (≤2.7%, versus 68.2% for MMP-8 at 100 ng/mL); antibody immobilization was confirmed by confocal immunofluorescence. A commercial sandwich ELISA on the same spike series gave a matched-matrix LOD of 41.1 ng/mL, nearly two orders of magnitude higher. This performance requires no metal coating, nanostructuring, label, or signal amplification, only a single wet-etching step on stock telecommunications fiber.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Construction of an Antifouling Electrochemical Biosensor Based on Bilateral Proline-Rich Peptide Scaffolds with Enhanced Stability for Detection in Complex Biofluids.Analytical chemistry · 2026
- Optical Fiber Needle Probes for In Situ-Distributed Biosensing Based on Optical Frequency Domain Reflectometry.ACS sensors · 2026
- Precise Early Diagnosis of Periodontal Disease via Microfluidic OECTs.Small (Weinheim an der Bergstrasse, Germany) · 2026
- A Superb Antifouling Electrochemical Biosensor Based on Macrocycle Encapsulation Strategy for Biomarker Analysis in Complex BiofluidsACS Sensors · 2025
- Experimental plasmonic sensing of malaria using an aluminum metasurfaceNanoscale Advances · 2026
- An automated fiber-optic SPR platform with a self-assembled peptide interface for sPD-L1 analysis.Journal of pharmaceutical and biomedical analysis · 2026