Optical Fiber Needle Probes for In Situ-Distributed Biosensing Based on Optical Frequency Domain Reflectometry.
Haohan Guo, Rongyang Zhu, Ji Liu, Qian Xu, Jinqi Deng, Kun Liu, Junfeng Jiang, Tiegen Liu,
School of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin300072, China. · International Joint Institute of Tianjin University , Fuzhou350205, China.
Key points
From the paper's conclusion- We propose an optical fiber needle probe for in situ distributed sensing of hepatocellular carcinoma (HCC) biomarker GPC3 in soft matter based on optical frequency domain reflectometry (OFDR).
Abstract
In situ detection is crucial for diagnosing lesions during surgery, endoscopy, or biopsy but has always been a challenge in medical diagnostics. Optical fiber biosensing needle probes, with their small size, can be nearly noninvasively guided to the lesion site for in situ detection. However, existing optical fiber biosensing probes are single-point sensors, unable to precisely locate lesions. We propose an optical fiber needle probe for in situ distributed sensing of hepatocellular carcinoma (HCC) biomarker GPC3 in soft matter based on optical frequency domain reflectometry (OFDR). The needle type probe is fabricated by integrating a polydopamine (PDA)-assisted anti-GPC3 antibody-functionalized micro/nano fiber into a metal needle with a lateral opening near the distal tip. Through differential-phase demodulation, calibration experiments with varying GPC3 concentrations reveal that the needle probe exhibits an 8 mm sensing length with a sensitivity of 0.0031 rad/(ng/mL). More importantly, the proposed needle probe achieves the precise spatial localization of both independent and simultaneous multiple 250-μm mimic lesions loaded by GPC3 in an agarose-glycerol hydrogel soft matter phantom with a spatial resolution of 25 μm and a limit of detection (LOD) of 3.23 ng/mL, which offers unparalleled advantages compared with existing biosensors. The proposed method provides a potential for in situ detection and localization of HCC or other lesions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Graphene Oxide-Functionalized Fiber Optic Biosensor for Breast Cancer Biomarker Detection: Toward Developing a Highly Sensitive Multi-Fluid Diagnostic Platform.ACS sensors · 2026
- Experimental plasmonic sensing of malaria using an aluminum metasurfaceNanoscale Advances · 2026
- High-Performance Optical Fiber SPR Biosensor for Label-Free Detection of miRNA-588 Toward Osteosarcoma Diagnosis.Advanced healthcare materials · 2026
- Gold nanowire-functionalized D-Shaped PCF-SPR sensor for ultrasensitive detection of biomarkersRadiation effects and defects in solids · 2026
- Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8).Biosensors · 2026
- U-shaped fiber-optic biosensor with gold nanoparticle-assisted signal amplification for allergy-related biomarker detection.Analytical and bioanalytical chemistry · 2026