A Spiking Neural Network for Non-Invasive Glucose Estimation on Wearable Bioimpedance Biosensors, with a Multiplication-Free Neuromorphic Path.
Matheus Willian Sprotte, Pedro Bertemes Filho
Department of Electrical Engineering, Santa Catarina State University (UDESC), Joinville 89219-710, Brazil.
Key points
From the paper's conclusion- Together, these results demonstrate that SNNs offer a clinically auditable, self-calibrating, and memory-efficient path to continuous glucose estimation on embedded wearable devices.
Abstract
Wearable glucose monitoring demands low-power local processing, but conventional neural networks rely on energy-intensive multiply-accumulate (MAC) operations that limit battery life. This study shows that a Spiking Neural Network (SNN), built on a regression-adapted Leaky Integrate-and-Fire (LIF) neuron, can estimate blood glucose from multi-frequency bioimpedance and auxiliary biosignals with clinically auditable accuracy at low computational and memory cost. Using data from 98 patients (717 measurements, eGluco3 device, Azambuja Hospital, Brusque, Brazil) evaluated by 5-fold walk-forward cross-validation under ISO 15197:2013, three main findings emerge. First, a new calibration method-the Patient Fingerprint, built from each patient's first K sensor readings-outperforms conventional one-hot patient encoding (14.2 ± 2.6 mg/dL vs. 15.4 ± 3.3 mg/dL mean absolute error) and, unlike one-hot, requires only these K readings rather than the patient's presence in the training set; a leave-patients-out analysis confirms that the fingerprint captures individual physiology and that unseen-patient accuracy improves with calibration depth but remains clinically insufficient (MAE 94.8→65.9 mg/dL from K=3 to K=5), positioning clinical-grade cross-patient generalization on a larger cohort as the primary scaling axis. Second, the direct-injection fingerprint model reaches 100% of the samples within Consensus Error Grid Zones A+B across all validation folds (the rate-coding variant reaches 98.8%, just below the 99% Criterion B threshold), without requiring any demographic or clinical metadata; sensor history alone renders such records redundant; and Criterion A, however, stays below the 95% normative threshold, so the results support clinical safety rather than formal certification. Third, replacing the analog input encoding with a multiplication-free rate-coding scheme removes all first-layer MAC operations at a cost of 2.7 mg/dL additional error; because the additional microticks raise the total operation count, this defines a design lever whose energy payoff is specific to neuromorphic hardware rather than a net saving on conventional microcontrollers. Together, these results demonstrate that SNNs offer a clinically auditable, self-calibrating, and memory-efficient path to continuous glucose estimation on embedded wearable devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals.Frontiers in medical technology · 2026
- Layer-wise hybrid binary–stochastic computing architecture for energy-efficient diabetes prediction on FPGAFrontiers in Electronics · 2026
- Neuromorphic Cardiac Sensing: A Bio-Inspired Spiking Neural Network with Sensory-Adaptive Encoding for Energy-Efficient Arrhythmia Detection from ECG and PPG Signals.Biomimetics (Basel, Switzerland) · 2026
- Photoplethysmography-based glucose estimation with feature selectionbioRxiv · 2026
- Camera-based HbA1c estimation using remote photoplethysmography: development, independent evaluation, and baseline comparator analysis.Frontiers in digital health · 2026
- Machine Learning-Aided Microwave Sensing for Blood Glucose Detection: Data Information Enhancement from Reduced Measurement Set.Biosensors · 2026