Design and Performance Analysis of 3RSS/S Ankle Rehabilitation Robot
Ahlem Hamel, Ridha Kelaiaia, Allaoua Brahmia, Adlen Kerboua, Ameur Latreche
Key points
From the paper's conclusion- This paper deals with the design and performance analysis of a 3RSS/S parallel robot for ankle rehabilitation.
Abstract
Background/Objectives: Ankle rehabilitation robotics has garnered a lot of interest because of its ability to improve therapeutic outcomes and enable quantitative patient monitoring. The ankle has a complex biomechanical system, so the design needs to have accurate kinematics, structural stiffness, and biomechanical compatibility. This paper deals with the design and performance analysis of a 3RSS/S parallel robot for ankle rehabilitation. Methods: A multi-objective optimization framework is presented for simultaneous optimization of workspace volume, kinematic accuracy and structural stiffness. The topology of the 3-DOF parallel mechanism is presented, and its geometric model and Jacobian matrix are derived. The optimization problem is solved using NSGA-II and the compromise solution is selected using TOPSIS. Results: For the adopted geometric, joint and actuator-compliance models, the chosen design yields an orientation-workspace measure of WV=0.1342rad3, a global Jacobian-conditioning index of ηJ=1.0812 and a global stiffness-conditioning index of ηS=1.1874. Numerical verification shows that the prescribed clinical orientation range is covered, that the clinical workspace volume Vclinical=0.1275rad3 is strictly contained in the reachable workspace, and that the chosen solution is insensitive to the assumed geometrical tolerances. Conclusions: These simulation-based results motivate prototype development and subsequent experimental kinematic, stiffness, safety, and human–robot interaction validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Analysis of a Variable Stiffness Cable-driven Upper Limb Rehabilitation Robot*Journal of Physics: Conference Series · 2026
- Multi-Objective Bio-Inspired Optimization of a Passive Ankle Exoskeleton with a Geometry-Derived Moment Arm.Biomimetics (Basel, Switzerland) · 2026
- Mechatronic Design, Biomechanical Analysis, and Kinematic Validation of a Continuous Passive Motion Slider–Crank–Lead Screw System for Lower-Limb Rehabilitation: From Post-Stroke Therapy to Potential Post-Spaceflight ReconditioningTechnologies · 2026
- Trajectory Planning Method for Fracture Reduction of Parallel Robots Based on DMP and APFIEEE Transactions on Automation Science and Engineering · 2026
- Model predictive controller design for speed tracking of walking training rehabilitation robotJournal of Physics: Conference Series · 2026
- Subject-specific kinematic analysis of a total ankle arthroplasty implant.Frontiers in bioengineering and biotechnology · 2026