Key points
From the paper's conclusion- This study developed and preliminarily validated a robotic Continuous Passive Motion (CPM) system intended for lower-limb rehabilitation in post-stroke adult patients with hemiplegia.
Abstract
This study developed and preliminarily validated a robotic Continuous Passive Motion (CPM) system intended for lower-limb rehabilitation in post-stroke adult patients with hemiplegia. Building upon a previous redesign and simulation stage using a virtual patient model, an adjustable structure made of AISI 316L stainless steel was fabricated, integrating the mechanical, electronic, and control subsystems for passive knee and ankle mobilization through a lead screw mechanism driven by a NEMA23 stepper motor, a TB6600 driver, and an ESP32 microcontroller operating under an open-loop feedforward control scheme. As a preliminary stage prior to clinical evaluation, functional validation was conducted through three knee therapy tests, two with a healthy adult volunteer and one under unloaded conditions, using different angular ranges (90–130°, 30–26°, and 50–70°). The device successfully executed the programmed movements without mechanical or electronic failures, completing all three repetitions in each session and recording observed differences ranging from 2.00% to 11.54% between the programmed and measured joint angles. These results demonstrate the preliminary technical feasibility of the proposed prototype. The present validation was limited to a single adult volunteer and three knee-motion tests. Future work will include validation with volunteers representing different anthropometric profiles (1.55–1.75 m), verification of emergency stop response times below 100 ms, and the incorporation of encoder-based position feedback as preliminary steps toward subsequent clinical evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Evaluation of a Trunk–Limb Robotic Exoskeleton for Gait Rehabilitation in Cerebral PalsyBiomimetics · 2026
- Design and Analysis of a Variable Stiffness Cable-driven Upper Limb Rehabilitation Robot*Journal of Physics: Conference Series · 2026
- Design and Initial Evaluation of a Low-Cost Microprocessor-Controlled Ankle ProsthesisSensors · 2026
- An Active Knee–Ankle–Foot Orthosis With Torque‐Dense, Low‐Impedance Knee ActuationAdvanced Intelligent Systems · 2026
- Sliding Mode Control Application in Knee and Lower-Limb Exoskeletons: A ReviewElectronics · 2026
- Design and Bench Evaluation of a Sensor-Integrated Prosthetic-Leg Prototype.Sensors (Basel, Switzerland) · 2026