From the paper's conclusion- Static guides showed lower reported linear deviations than dynamic navigation, but all comparisons were indirect and measurement methods differed; certainty of evidence was moderate for s-CAS and very low for d-CAS.
Abstract
Computer-guided insertion of palatal miniscrews can be performed with static surgical templates (s-CAS) or dynamic optical navigation (d-CAS), but their clinical transfer accuracy has not been systematically compared. This systematic review evaluated the three-dimensional placement accuracy of palatal miniscrews inserted with s-CAS and d-CAS. Following PRISMA 2020 (PROSPERO CRD420261380693), PubMed, Cochrane Library, Scopus, Web of Science, LILACS and Embase were searched in April–May 2026 for prospective clinical studies reporting angular, coronal and apical deviations between planned and achieved positions. Risk of bias was assessed with RoB 2 and ROBINS-I, certainty of evidence with GRADE, and findings were synthesized narratively. Nine studies (three randomized trials; up to 289 patients and 588 miniscrews) were included. Mean deviations of the s-CAS arms ranged from 3.61° to 7.15° (angular), 0.73 to 1.10 mm (coronal) and 1.25 to 2.00 mm (apical); those of the d-CAS arms, all from a single research group, ranged from 4.33° to 13.30°, 1.87 to 3.02 mm and 1.87 to 3.76 mm, respectively. In single randomized trials, full-arch guides reduced linear deviations and pressure-moulded guides reduced angular deviation. Static guides showed lower reported linear deviations than dynamic navigation, but all comparisons were indirect and measurement methods differed; certainty of evidence was moderate for s-CAS and very low for d-CAS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative accuracy of dynamic navigation versus static surgical guides for dental implant placement: an in vitro assessment of free-end and non-free-end configurationsScientific Reports · 2026
- Positional Accuracy and Safety of Digitally Guided Orthodontic Mini-Implant Placement: A Systematic Review and Exploratory Meta-AnalysisHygiene · 2026
- Accuracy of Planned Versus Actual Implant Placement Using Different Implant Systems: A Systematic Review of Angulation and Positional Deviations.Journal of maxillofacial and oral surgery · 2026
- Accuracy of Metallic-Sleeved Versus Sleeve-Free Surgical Guides in Static Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2026
- Impact of Level of Guidance on the Accuracy of Static Computer-Assisted Implant Surgery (s-CAIS): An In Vitro Study.Clinical oral implants research · 2026
- Sources of Error in Static Computer-Assisted Implant Surgery: A Critical Review of Error Propagation Through the Digital Workflow.Dentistry journal · 2026