Total Hip Arthroplasty on Tumor Treating Fields Delivery for Ovarian Carcinoma: A Finite Element Study.
Olivia Liang, Edwin Lok, Bassel G Diebo, Monika Haack, Eric T Wong
Brain Tumor Center & Neuro-Oncology Unit, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA. · Division of Hematology/Oncology, Departments of Medicine, Brown University Health & Rhode Island Hospital, Providence, RI 02903, USA.
Key points
From the paper's conclusion- Background: Tumor Treating Fields (TTFields) are being investigated for pelvic malignancies, while total hip arthroplasty (THA) is increasingly common.
Abstract
Background: Tumor Treating Fields (TTFields) are being investigated for pelvic malignancies, while total hip arthroplasty (THA) is increasingly common. This study evaluated whether THA prosthetic materials influence TTFields distribution and target dosimetry in ovarian tumors. Methods: Patient-specific finite element models were generated from computed tomography datasets of four patients with ovarian carcinoma. Three-dimensional simulations assigned cortical bone, Ti6Al4V titanium alloy, Co28Cr6Mo cobalt-chromium alloy, or tantalum to both femurs or to a single femur. Electric field (E), specific absorption rate (SAR), and current density (CD) were quantified in the clinical target volume (CTV), femur, and skin using 95%, 50%, and 5% volume-based metrics. Results: Bilateral implant properties produced minor CTV dosimetric changes, with mean and median percent differences generally within ±3.4% across metrics. Tantalum closely approximated cortical bone, typically within ±1%. Implants substantially reduced femoral E and SAR distributions while increasing CD. Skin exposure decreased modestly across 95% and 50% volumes. Unilateral implants similarly preserved CTV dosimetry within ±5.8%, while the contralateral cortical femur changed by less than 3.2%. Conclusions: In our preliminary analysis, THA materials altered femoral distributions of TTFields while largely preserving relevant CTV dosimetry in both bilateral and unilateral configurations. Tantalum closely approximated cortical bone and produced slightly greater skin reductions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and biomechanical investigation of a patient-specific total talar prosthesis for total talar replacement: A finite element analysis.The International journal of artificial organs · 2026
- Intercalary Allograft Reconstruction of the Femur: A Cadaveric Comparison of Intramedullary and Plate Fixation TechniquesJournal of Orthopaedic Research® · 2026
- Risk of Intraoperative Periprosthetic Femoral Fracture According to Cementless Femoral Stem Geometry: A Cohort Study Based on the Radaelli ClassificationCureus · 2026
- Comparative host-graft biomechanics of osteoarticular allografts and allograft-prosthesis composites after distal femoral tumor resection.Journal of orthopaedic surgery and research · 2026
- TP6.4 Uncemented Hip Resurfacing in Active Patients With Large Femoral Head Bone Defects: Outcomes From 235 CasesJournal of Hip Preservation Surgery · 2026
- 4D-printed fibre-reinforced scaffolds with high elasticity and sustained estradiol release for uterine tissue regenerationVirtual and Physical Prototyping · 2026