An Incremental Denoising Convolutional Autoencoder for Adaptive One-Dimensional Biosignal Reconstruction in Wearable Devices.
Evangelin Dasan, Marshal Raj, Seok-Bum Ko
AAA College of Engineering and Technology, Sivakasi 626005, India. · Indian Computer Emergency Response Team, New Delhi 110003, India.
Key points
From the paper's conclusion- Experimental results demonstrate that the proposed method achieves improved reconstruction accuracy and reduced reconstruction loss, demonstrating its potential for adaptive biosignal processing in resource-constrained wearable devices.
Abstract
Deep learning has significantly enhanced one-dimensional biosignal processing in wearable devices by enabling accurate and intelligent signal analysis. Wearable devices operate using optimized model parameters obtained through offline training. However, physiological variations among users necessitate periodic model updates to maintain performance. Conventional retraining requires storing both existing and newly acquired datasets, leading to increased memory consumption and computational overhead, which limits its deployment in resource-constrained wearable devices. To address this challenge, this work proposes an incremental learning framework based on an incremental denoising convolutional autoencoder (I-D-CAE) that incrementally updates the model using newly available data while preserving previously learned knowledge, thereby avoiding the need to retain the complete historical dataset. The proposed framework adapts to newly available data while retaining previously learned model parameters and maintaining a fixed model-parameter size. Experimental results demonstrate that the proposed method achieves improved reconstruction accuracy and reduced reconstruction loss, demonstrating its potential for adaptive biosignal processing in resource-constrained wearable devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Biosignals to Bedside: A Review of Real-Time Edge Machine Learning for Wearable Health MonitoringBioengineering · 2026
- Development and validation of two-level budget-aware update policies for on-device continual ECG personalizationPhysiological Measurement · 2026
- 12-lead ECG synthesis from reduced lead set using multi-lead convolutional autoencoderCurrent Directions in Biomedical Engineering · 2026
- PhysioWave-T: Token-Efficient Wavelet Foundation Models for BiosignalsarXiv · 2026
- ArrythML-II: An Optimized TinyML Framework for ECG Arrhythmia Detection and Multi-Class Beat Classification on Wearable DevicesarXiv · 2026
- RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming BiosignalsarXiv · 2026