Tongji Medical College of Huazhong University of Science and Technology, Tongji Medical College, Huazhong University of Science and Technology, No. 13 Hangkong Road, Wuhan 430030, Hubei, China, Wuhan, 430030, China. · Jilin University College of Materials Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun, Changchun, 130022, China.

Key points

From the paper's conclusion
  • We develop and validate an update policy that decouples update cost from update value.
Approach: After prediction and label feedback on each 64-beat window, a token-bucket controller first adapts the personal head at 4.9% of the full-update cost, measures the residual error, and escalates to the backbone tail when needed and affordable.

Abstract

Budgeted-update policies for on-device ECG personalization treat a gradient update as atomic: when the per-window budget cannot cover a full update, all learning on that window is forfeited. We develop and validate an update policy that decouples update cost from update value. Approach: After prediction and label feedback on each 64-beat window, a token-bucket controller first adapts the personal head at 4.9% of the full-update cost, measures the residual error, and escalates to the backbone tail when needed and affordable. The paid head update is retained when the tail is unaffordable. Development on MIT-BIH and INCART was followed by validation on 72 complete SVDB recordings and 32 European ST-T patients, with three learning seeds and paired cluster-bootstrap intervals. Main results: The two-level structure improved accuracy by approximately 2.8-3.2 percentage points (pp) over matched-signal atomic gating across MIT-BIH, INCART and SVDB. At ρ=0.25, total MAC savings were approximately 41-48%. On SVDB, head-balanced gained 3.132 pp accuracy and 5.985 pp macro-F1 over bal-gate, and 1.176/2.169 pp over an approximately rate-matched head-update control. It used 30.73% fewer intervention windows than per-window head updating, with gains of 0.103/0.163 pp. Accuracy gains over the adapted RCCDA gap gate reached 9.25-23.37 pp in development. EDB macro-F1 gains rose from 0.015 to 8.147 pp across burden strata. STM32F746ZG measurements quantified latency and RAM. Significance: Staged update allocation provides a practical policy for supervised ECG personalization under limited on-device computation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers