The Use of Artificial Intelligence for Estimating Trabecular-Iris Angle from Slit-Lamp Images Developed Using Anterior-Segment Optical Coherence Tomography.
Takahiro Mizukami, Jun Ohashi, Hiroki Nishimura, Ryota Yokoiwa, Yuji Takayanagi, Hirotsugu Soga, Shintato Nakayama, Eisuke Shimizu
Yokohama Keiai Eye Clinic, Yokohama 2400065, Japan. · OUI Inc., Tokyo 1070062, Japan.
Key points
From the paper's conclusion- Conclusions: These findings demonstrate the feasibility of estimating TIA500 from smartphone-based slit-lamp images.
Abstract
Background: Narrowing of the trabecular-iris angle (TIA) is a key anatomical feature of primary angle-closure disease and contributes to impaired aqueous humor outflow; however, conventional angle assessment requires specialized expertise or costly imaging equipment. This study aimed to develop an artificial intelligence model for quantitative TIA estimation from anterior-segment images acquired with a smartphone-attached slit-lamp microscope. Methods: In this retrospective study, 127,512 candidate frames were extracted from anterior-segment videos obtained from 2654 eyes. After automated diagnosability filtering, 59,412 frames suitable for TIA500 estimation were retained and assigned to the training, validation, and test datasets using patient-level grouping. A ResNet50-based model was trained to estimate inferior, nasal, and temporal TIA500 values using the corresponding measurements obtained by anterior-segment optical coherence tomography (AS-OCT) as the ground-truth reference. Model performance was evaluated by comparing the AI-predicted values with the AS-OCT measurements using mean absolute error (MAE), root mean squared error (RMSE), Spearman's rank correlation coefficient, and the intraclass correlation coefficient (ICC). Results: Per-eye MAEs were 7.01° ± 5.69°, 7.28° ± 5.80°, and 7.90° ± 6.37° for inferior, nasal, and temporal TIA, respectively. Corresponding correlations with reference measurements were 0.683, 0.696, and 0.646, while ICCs were 0.769, 0.764, and 0.743 (all p < 0.001). Conclusions: These findings demonstrate the feasibility of estimating TIA500 from smartphone-based slit-lamp images. However, the moderate correlations with AS-OCT measurements indicate that the present model is not yet sufficiently accurate for independent clinical diagnosis or screening, and further model improvement and external validation are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Use of an Artificial Intelligence Model for Automated Measurement of the Anterior Segment by Ultrasound Biomicroscopy in ICL Calculation.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Anterior Chamber Angle Alterations in Bilateral Acute Iris Transillumination Syndrome.Ocular immunology and inflammation · 2026
- Machine-learning prediction of high implantable collamer lens vault using angle-to-angle anatomy: a patient-grouped internal validation study.Frontiers in cell and developmental biology · 2026
- Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Real-World External Evaluation of an OCT Image Analysis System (AI-CO) in Relation to Humphrey Visual Field Mean DeviationmedRxiv · 2026
- Artificial Intelligence–Derived Biomechanical Index for Early Corneal Ectasia Detection: Advancing Beyond TomographyOphthalmology Science · 2025