The Use of Artificial Intelligence for Estimating Trabecular-Iris Angle from Slit-Lamp Images Developed Using Anterior-Segment Optical Coherence Tomography.

Takahiro Mizukami, Jun Ohashi, Hiroki Nishimura, Ryota Yokoiwa, Yuji Takayanagi, Hirotsugu Soga, Shintato Nakayama, Eisuke Shimizu

Yokohama Keiai Eye Clinic, Yokohama 2400065, Japan. · OUI Inc., Tokyo 1070062, Japan.

Observational · n=2,654

Key points

From the paper's conclusion
  • Conclusions: These findings demonstrate the feasibility of estimating TIA500 from smartphone-based slit-lamp images.

Abstract

Background: Narrowing of the trabecular-iris angle (TIA) is a key anatomical feature of primary angle-closure disease and contributes to impaired aqueous humor outflow; however, conventional angle assessment requires specialized expertise or costly imaging equipment. This study aimed to develop an artificial intelligence model for quantitative TIA estimation from anterior-segment images acquired with a smartphone-attached slit-lamp microscope. Methods: In this retrospective study, 127,512 candidate frames were extracted from anterior-segment videos obtained from 2654 eyes. After automated diagnosability filtering, 59,412 frames suitable for TIA500 estimation were retained and assigned to the training, validation, and test datasets using patient-level grouping. A ResNet50-based model was trained to estimate inferior, nasal, and temporal TIA500 values using the corresponding measurements obtained by anterior-segment optical coherence tomography (AS-OCT) as the ground-truth reference. Model performance was evaluated by comparing the AI-predicted values with the AS-OCT measurements using mean absolute error (MAE), root mean squared error (RMSE), Spearman's rank correlation coefficient, and the intraclass correlation coefficient (ICC). Results: Per-eye MAEs were 7.01° ± 5.69°, 7.28° ± 5.80°, and 7.90° ± 6.37° for inferior, nasal, and temporal TIA, respectively. Corresponding correlations with reference measurements were 0.683, 0.696, and 0.646, while ICCs were 0.769, 0.764, and 0.743 (all p < 0.001). Conclusions: These findings demonstrate the feasibility of estimating TIA500 from smartphone-based slit-lamp images. However, the moderate correlations with AS-OCT measurements indicate that the present model is not yet sufficiently accurate for independent clinical diagnosis or screening, and further model improvement and external validation are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The Use of Artificial Intelligence for Estimating Trabecular-Iris Angle from Slit-Lamp Images Developed Using Anterior-Segment Optical Coherence Tomography — Science Skim