Identification of Gait Abnormalities in Patients with Hip Osteoarthritis Using a Monocular Vision 3D Motion Capture System.
Kento Sabashi, Ryo Ueno, Mina Samukawa, Harukazu Tohyama
Department of Rehabilitation, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-Ku, Sapporo 060-8648, Hokkaido, Japan. · Department of Research and Development, ORGO Inc., 2-7, Odori Nishi 18, Chuo-Ku, Sapporo 060-0042, Hokkaido, Japan.
Key points
From the paper's conclusion- These findings suggest that AI-driven video-based kinematic measurements show no clear difference in the accuracy between patients with hip OA and healthy participants, and demonstrate the potential to identify gait abnormalities.
Abstract
This study aimed to compare the accuracy of video-based kinematic measurements using artificial intelligence (AI) between patients with hip osteoarthritis (OA) and healthy participants, and to compare the gait abnormality estimated from video data with that calculated using optical three-dimensional motion capture (MOCAP) data. This study used open-access datasets of MOCAP and video data including 20 patients with hip OA and 20 healthy participants. Video data were processed using the MYoACT application to extract marker data. The mean absolute error (MAE) of joint angles between MOCAP and MYoACT data was calculated. In patients with hip OA, the modified Gait Abnormality Score (mGAS) for each joint angle was calculated by averaging the absolute differences between each patient's value and the mean value of healthy participants, divided by the standard deviation of healthy participants, across the entire gait cycle. No significant difference in the MAE was observed between groups. In patients with hip OA, the mGAS showed no significant difference between MYoACT and MOCAP data. These findings suggest that AI-driven video-based kinematic measurements show no clear difference in the accuracy between patients with hip OA and healthy participants, and demonstrate the potential to identify gait abnormalities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Joint Kinematics and Spatiotemporal Gait Parameters Between Markerless and Marker-Based Motion Capture in a Large Knee Osteoarthritis Cohort.Annals of biomedical engineering · 2026
- AI-driven correction of video-derived gait kinematics in healthy older adults.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Gait assessment using a 2D video-based pose estimation app in comparison to a markerless motion capture system in subjects with osteoarthritis of the knee - a pilot study.Frontiers in bioengineering and biotechnology · 2026
- A Preliminary Concurrent Validation of a Portable Markerless Motion Capture System Against Three-Dimensional Gait Analysis Following Total Hip and Knee Arthroplasty.Sensors (Basel, Switzerland) · 2026
- Robustness and Interpretability of Deep Learning on Raw Gait Marker Trajectories for Osteoarthritis ClassificationApplied Sciences · 2026
- Hip kinematics are associated with gait speed in knee osteoarthritis: A smartphone-based markerless motion capture study.Clinical biomechanics (Bristol, Avon) · 2026