Dark-Blood Adiabatic T1ρ Mapping of the Heart Using Combined Non-Selective and Slice-Selective RF Pulses at 3T.
Chiara Coletti, Joao Tourais, Anastasia Fotaki, Yidong Zhao, Yi Zhang, Christal van de Steeg-Henzen, Qian Tao, Claudia Prieto,
Department of Imaging Physics, Delft University of Technology, 2628 CH Delft, The Netherlands. · Department of Biomedical Engineering, King's College London, London WC2R 2LS, UK.
Key points
From the paper's conclusion- In this work, we study the effectiveness of dark-blood (DB) contrast in adiabatic T1ρ (T1ρ,adiab) mapping at 3T, using slice-selective and non-selective adiabatic spin-lock pulses.
Abstract
T1ρ mapping is emerging as a potential, contrast-free alternative to late gadolinium enhancement (LGE) for assessment of myocardial viability. However, strong signal contributions from the blood pool can impede quantitative evaluation at the (sub)endocardium. In this work, we study the effectiveness of dark-blood (DB) contrast in adiabatic T1ρ (T1ρ,adiab) mapping at 3T, using slice-selective and non-selective adiabatic spin-lock pulses. Adiabatic DB-T1ρ,adiab preparations consisted of an odd number of slice-selective adiabatic full passage (AFP) pulses, followed by a final, non-selective AFP pulse. This preparation induces T1ρ,adiab decay within the imaging slice while inverting the magnetization outside. A delay (δ) between preparation and imaging allowed for relaxation and inflow of the inverted blood to achieve DB contrast. Bias and precision of DB- and bright-blood (BB)-T1ρ,adiab were compared in phantom and in healthy subjects (n = 10). Blood suppression efficacy and apparent myocardial thickness in DB imaging were investigated in simulations, phantom, and in vivo. The clinical feasibility of DB-T1ρ,adiab mapping was evaluated in a small cohort of patients (n = 7) with suspected cardiovascular diseases. DB-T1ρ,adiab values were in agreement with reference BB-T1ρ,adiab values in phantom (myocardium-like vial BB: 219.27 ± 4.80 ms, DB: 218.09 ± 8.22 ms) and in healthy subjects (BB: 182.32 ± 28.27 ms, DB: 183.49 ± 45.54 ms). A moderate increase in intra-(wCVi,r) and inter-scan variability (wCVi¯) was observed in the DB method, compared with conventional BB imaging, for phantom and healthy subjects (in vivo wCVi,r BB: 15.51 ± 2.65%, DB: 24.82 ± 4.18%; in vivo wCVi¯ BB: 3.38 ± 0.86%, DB: 7.24 ± 2.55%). Longer delay times improved blood suppression in vivo for DB-T1ρ,adiab, albeit at increased intra-scan variability in phantom and in vivo (DB wCVi,r for δ = 0 ms: 4.90 ± 0.83% in phantom, 13.44 ± 2.91% in vivo, for δ = 600 ms: 8.14 ± 1.88% in phantom, 26.25 ± 5.19% in vivo). Average apparent myocardial thickness was slightly higher when using DB-T1ρ,adiab compared with BB-T1ρ,adiab (BB: 7.33 ± 2.05 mm, DB: 7.99 ± 2.46 mm). DB-T1ρ,adiab maps yielded comparable image quality to BB-T1ρ,adiab maps in patients. DB-T1ρ,adiab mapping represents an alternative to BB-T1ρ,adiab for myocardial assessment with the potential for improved visualization of the (sub-)endocardium.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of left atrial native T1 values using non-contrast 3.0 T cardiac magnetic resonance imaging: a feasibility and reproducibility study.BMC medical imaging · 2026
- Cardiovascular magnetic resonance stress T1 mapping for the detection of myocardial ischemia and significant coronary artery disease: validation against [15O]H2O PET and fractional flow reserveEuropean Heart Journal · 2026
- Cross‐Vendor Validation of Proton Density Fat Fraction and T₁ Mapping Using a Combined Proton Density Fat Fraction— T1 PhantomJournal of Magnetic Resonance Imaging · 2026
- Robust Quantification of Intraventricular Flow Using Ultrafast Vector Doppler Imaging in a Murine Model of Dilated Cardiomyopathy.American journal of physiology. Heart and circulatory physiology · 2026
- T2 estimation from MOLLI acquisitionsarXiv · 2026
- Quantitative ventricular trabeculation assessment in cardiac MRI: optimised blood-pool segmentation, box-counting fractal analysis and non-fractal measurementsThe International Journal of Cardiovascular Imaging · 2026