Assessment of left atrial native T1 values using non-contrast 3.0 T cardiac magnetic resonance imaging: a feasibility and reproducibility study.
Nonthikorn Theerasuwipakorn, Nabhat Noparatkailas, Piyanun Sanguanwong, Sittinop Titichoatrattana, Rattanaporn Prasertdumrongchai, Yongkasem Vorasettakarnkij, Monravee Tumkosit, David C Wendell,
Division of Cardiovascular Medicine, Department of Medicine, Faculty of Medicine, Cardiac Center, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok, 10330, Thailand. · Department of Radiology, Faculty of Medicine, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok, Thailand.
Key points
From the paper's conclusion- We evaluated the feasibility and reproducibility of LA T1 measurements using non-contrast 3.0-T cardiac magnetic resonance (CMR), thereby providing a methodological foundation for future studies of atrial tissue characterization.
Abstract
PURPOSE: Atrial cardiomyopathy (ATC) is characterized by structural and functional atrial remodeling and is associated with adverse cardiovascular outcomes. Native T1 mapping has emerged as a sensitive technique for tissue characterization; however, data on left atrial (LA) native T1 mapping remain limited. We evaluated the feasibility and reproducibility of LA T1 measurements using non-contrast 3.0-T cardiac magnetic resonance (CMR), thereby providing a methodological foundation for future studies of atrial tissue characterization. METHODS: Healthy volunteers in sinus rhythm underwent non-contrast 3.0-T CMR, including native T1 mapping using a modified Look-Locker inversion recovery (5s(3s)3s MOLLI) sequence. LA native T1 values were measured in the 2-, 3-, and 4-chamber long-axis views. Two independent specialists measured LA native T1 values using regions of interest placed within the inner 2 reconstructed pixels of the LA wall to minimize in-plane partial volume effects. Feasibility was assessed by the proportion of measurable studies, and reproducibility by intra- and inter-observer intraclass correlation coefficients (ICC). Additional analyses were performed to assess potential blood-pool contamination. RESULTS: Forty volunteers (50% female; mean age 33.6 ± 6.1 years; body mass index of 22.7 ± 3.2 kg/m²) were included. LA native T1 values were measurable in 62.5%, 95.0%, and 75.0% of subjects in the 2-, 3-, and 4-chamber views, respectively, identifying the 3-chamber view as the most feasible imaging plane. Mean LA native T1 values were consistent across views (1,441-1,448 ms; all p > 0.05) without gender difference. Reproducibility was excellent, with intra-observer ICCs of 0.921-0.940 and inter-observer ICCs of 0.894-0.920. Agreement between views was good (ICC 0.709-0.878) without significant proportional bias. Blood-pool T1 values were substantially higher than LA T1 values (1,859-1,868 ms vs. 1,441-1,448 ms) and showed no significant correlation. Validation analyses demonstrated a progressive increase in blood-pool T1 values with increasing distance from the LA wall, supporting measurement specificity. CONCLUSION: Non-contrast T1 mapping enables feasible and highly reproducible quantification of LA native T1 values. The 3-chamber view demonstrated the highest measurability and may be the preferred imaging plane for LA tissue characterization. These findings provide a methodological framework for future investigations of ATC and other atrial diseases. CLINICAL TRIAL NUMBER: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Left Ventricular Myocardial Fibrosis and Edema in Atrial Fibrillation Using Cardiovascular Magnetic Resonance.Journal of visualized experiments : JoVE · 2026
- Quantitative assessment of left atrial fibrosis and its relationship with heart failure with preserved ejection fraction in patients with atrial fibrillation: insights from cardiac MRIEuropean Heart Journal · 2026
- CMR-derived left atrial reservoir strain and the LAVI/LVEF ratio are associated with 30-day readmission in atrial fibrillation: the CMRRADAR-AF retrospective cohort study.Frontiers in cardiovascular medicine · 2026
- Native myocardial T1 reference values in a tunisian cohort using MOLLI and SMART1Map : List of Authors.Scientific reports · 2026
- Dark-Blood Adiabatic T1ρ Mapping of the Heart Using Combined Non-Selective and Slice-Selective RF Pulses at 3T.Bioengineering (Basel, Switzerland) · 2026
- Myocardial T1 Mapping at 3 T: A Comparison of MOLLI and ShMOLLI across Healthy Volunteers and Various Cardiovascular Pathologies.Radiology · 2026