Frequency and Direction-Dependent Shear-Wave Responses in Ex Vivo Tissues Measured by a Time-of-Flight Device.
Jotham Josephat Kimondo, Ziang Feng, Jie Yang, Qiang Lu, Sandra Pérez-Buitrago, Zhe Wu
School of Life Sciences and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China. · Department of Medical Ultrasound, West China Hospital of Sichuan University, Chengdu 610041, China.
Key points
From the paper's conclusion- The device detected frequency- and direction-dependent responses in averaged ex vivo signals, supporting its feasibility as a controlled research platform.
Abstract
Shear-wave time-of-flight (TOF) measurement enables controlled assessment of frequency-dependent wave propagation, but its feasibility in biological tissues remains insufficiently established. This study evaluated whether a custom shear-wave TOF device could detect frequency- and direction-dependent responses in ex vivo tissues. Three porcine liver samples and three chicken breast samples were examined. Chicken breast was measured with propagation parallel and perpendicular to visible muscle fibers. One-cycle sinusoidal excitations were applied at 40-160 Hz, with 50 acquisitions ensemble-averaged per sample-frequency measurement. TOF was estimated using Tx threshold detection and cumulative-energy-based Rx onset detection, and TOF-derived apparent shear-wave propagation speed was calculated from the Tx-Rx distance and the measured TOF. Frequency-dependent data were fitted using the Kelvin-Voigt fractional derivative model to obtain model-dependent KVFD fit parameters. Signal quality was assessed, and a preliminary descriptive comparison with HISKY EQTouch UD3000 (Wuxi Hisky Medical Technologies Co., Ltd., Wuxi, China) SWE was performed. All 63 averaged sample-frequency measurements satisfied the predefined primary-detection criteria. Mean apparent shear-wave speed was 3.145 m/s in porcine liver, 6.133 m/s in chicken breast measured parallel to the fibers, and 5.914 m/s in chicken breast measured perpendicular to the fibers, giving a parallel-to-perpendicular speed ratio of 1.037. Mean post-averaging, post-processing SNR ranged from 24.47 to 31.52 dB. The UD3000 comparison showed the same tissue ranking. The device detected frequency- and direction-dependent responses in averaged ex vivo signals, supporting its feasibility as a controlled research platform. Claims of absolute stiffness accuracy and intrinsic muscle anisotropy require independent calibration and validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Vivo Dispersion Sensing Using Wearable Ultrasound Shear-Wave Elastometry.IEEE transactions on ultrasonics · 2026
- Layer-Specific Shear Wave Elastography Reveals the Tissue Origin of MyotonPRO-Derived Muscle Stiffness.Diagnostics (Basel, Switzerland) · 2026
- Optical coherence elastography for shear wave characterization under temporal undersampling.Biomedical optics express · 2026
- Comparing the Statistics of High-Resolution Time-of-Flight-Based Shear Wave Speed Estimation in the Presence of Speckle Bias Using Shear Wave Slowness or Velocity.IEEE transactions on ultrasonics · 2026
- A Handheld Probe for Focused Shear Wave Transient Elastography.Annals of biomedical engineering · 2026
- A reduced viscoelastic FDTD formulation for ultrasound-driven shear wave propagation in soft tissue.ArXiv · 2026