Optical coherence elastography for shear wave characterization under temporal undersampling.
Nasser Ghaderi, Madita Göb, Nicolas Detrez, Faride Mousavi, Wolfgang Draxinger, Thomas De Kerf, Sam Van der Jeught, Ralf Brinkmann,
InViLab Research Group, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium. · Institute of Biomedical Optics, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.
Key points
From the paper's conclusion- We present an optical coherence elastography approach for Rayleigh surface wave measurement with a MHz swept-source optical coherence tomography (OCT) system, enabling high-frequency wave characterization under temporal undersampling.
Abstract
We present an optical coherence elastography approach for Rayleigh surface wave measurement with a MHz swept-source optical coherence tomography (OCT) system, enabling high-frequency wave characterization under temporal undersampling. Mechanically induced waves in a tissue-mimicking phantom were captured below the conventional temporal Nyquist sampling condition, while wave propagation was recovered from the spatial structure of the measured displacement field and analyzed using spatial Fourier-domain processing. With 6 μm lateral sampling and 0.4 ms frame intervals (2.44 kHz B-scan rate), at a representative depth of 0.5 mm, the measured mean Rayleigh-wave speed was 13.61 m/s, with a frame-to-frame standard deviation of 0.73 m/s across 1000 frames. The results were compared with a second wave speed estimation method based on phase-gradient analysis and further validated using laser Doppler vibrometry (LDV), showing agreement in estimated wave speeds between OCT and LDV within 7.75%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Frequency-response analysis complements quantitative wave-speed assessment in optical coherence elastography.Optics letters · 2026
- Fast Optical Coherence Elastography via Optimized Sampling Density With Preserved Accuracy.Journal of biophotonics · 2026
- Multi-frequency asynchronous optical coherence elastography by direct demodulation.Biomedical optics express · 2026
- Super-resolution wave-dispersion analysis in optical coherence elastography using multiple signal classification (MUSIC).Biomedical optics express · 2026
- Insight into phase-sensitive optical coherence tomography displacement measurement.Nature communications · 2026
- Optically bandlimited coherent lateral resampling for optical coherence tomography.Biomedical optics express · 2026