Bioengineering (Basel, Switzerland)

Effects of a Torsion-Adaptive Energy-Storing-and-Return Prosthetic Foot on Balance Control in Individuals with Transtibial Amputation: A Pilot Pre-Post Motion Analysis Study.

Ho-Yong Jeong, Hee Seung Yang, Yea-Eun Lee, Pyoung-Hwa Choi, Chan-Hyeok Jeong, Hui-Woo Choi, Young Lee

Department of Physical Medicine and Rehabilitation, Veterans Health Service Medical Center, Seoul 05368, Republic of Korea. · Veterans Health Service Medical Center, Center of Prosthetics and Orthotics, Seoul 05368, Republic of Korea.

Key points

From the paper's conclusion
  • This pilot pre-post motion analysis study examined the effects of the Intersection Foot® (IF), a torsion-adaptive ESAR prosthetic foot, on balance control in 10 male individuals with unilateral transtibial amputation.

Abstract

Individuals with transtibial amputation have impaired postural control due to limited ankle function. Conventional energy-storing-and-return (ESAR) prosthetic feet mainly support sagittal-plane mechanics and provide limited frontal-plane adaptability. This pilot pre-post motion analysis study examined the effects of the Intersection Foot® (IF), a torsion-adaptive ESAR prosthetic foot, on balance control in 10 male individuals with unilateral transtibial amputation. Three-dimensional motion analysis and force plate measurements were performed during five Berg Balance Scale-derived tasks. During sit-to-stand, IF reduced the mediolateral root mean square distance of center of pressure from 10.20 ± 3.59 to 8.29 ± 3.32 mm (p = 0.047) and the anteroposterior center of mass (CoM) range from 345.51 ± 31.72 to 326.45 ± 47.40 mm (p = 0.008). During tandem stance, IF increased mediolateral CoM range from 23.94 ± 18.77 to 55.99 ± 30.90 mm (p = 0.021), vertical CoM range from 4.14 ± 4.18 to 9.45 ± 7.72 mm (p = 0.038), and sound-side frontal-plane ankle ROM from 1.44 ± 1.20° to 2.48 ± 1.30° (p = 0.022). Overall, replacing the habitual feet with IF produced task-dependent biomechanical adaptations rather than uniform improvements in postural stability, suggesting reduced dynamic sway during sit-to-stand but increased whole-body and sound-limb compensatory motion during tandem stance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effects of a Torsion-Adaptive Energy-Storing-and-Return Prosthetic Foot on Balance Control in Individuals with Transtibial Amputation: A Pilot Pre-Post Motion Analysis Study — Science Skim