Intra-Session Repeatability of Static Pedobarometric Measurements: Analysis of Variability in Plantar Pressure Parameters and the Spatial Localization of the Center of Pressure and Peak Pressure.
Lucia Bednarčíková, Teodor Tóth, Monika Michalíková, Patrícia Gajdošová
Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Letná 1/9, 042 00 Košice, Slovakia. · Department of Languages, Technical University of Košice, Letná 1/9, 042 00 Košice, Slovakia.
Key points
From the paper's conclusion- Averaging multiple trials enhances measurement repeatability, suggesting that repeated static pedobarometric assessments may provide more consistent estimates of plantar pressure parameters.
Abstract
Static pedobarometry is widely used to assess plantar pressure distribution and postural control; however, its clinical interpretation depends on measurement repeatability and reliability. The aim of our article is to evaluate the repeatability of plantar pressure parameters and the spatial localization of the center of pressure (CoP) and peak pressure (PP) during static bipedal standing. Five healthy adults underwent 30 repeated static measurements using the Sidas Press-Cam platform under standardized laboratory conditions. Analyzed parameters included contact area, mean pressure, peak pressure, and the center of pressure coordinates. Repeatability was assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland-Altman analysis. Contact area showed high single-measure repeatability (ICC (2, 1) = 0.90). Peak pressure and mean pressure demonstrated moderate repeatability for single trials but excellent repeatability when averaged (ICC (2, k) = 0.97-0.996). The center of pressure exhibited greater mediolateral than anteroposterior variability. Peak pressure localization remained stable within 3 SD and predominantly on the dominant limb. Averaging multiple trials enhances measurement repeatability, suggesting that repeated static pedobarometric assessments may provide more consistent estimates of plantar pressure parameters. However, these findings should be interpreted as preliminary evidence from an intra-session repeatability study due to the limited sample size.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A framework for robust spatiotemporal analysis of dynamic plantar pressure measurement over the stance phase of gait.Journal of biomechanics · 2026
- From pressure to force: a device-independent, predictive model of plantar loading for personalized orthoses.Frontiers in bioengineering and biotechnology · 2026
- Agreement of 11-Sensor Plantar-Pressure Configurations with a Full Pedar-X Array for Estimating Center of Pressure and Pressure-Derived Vertical Force in Individuals with Flatfoot During Walking and Running.Sensors (Basel, Switzerland) · 2026
- Clinical Foot Findings and Plantar Pressure Assessment in Type 2 Diabetes: A Cross-Sectional Comparison of Static and Dynamic MeasuresExperimental and Applied Biomedical Research (EABR) · 2026
- Clinical Reference Values for Dynamic Plantar Pressure Assessment in Healthy Young Adults: Sex Differences and Bilateral Symmetry.Life (Basel, Switzerland) · 2026
- From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure MonitoringSensors · 2025