Clean-Booth Dynamics: Investigating the Impact of Blower Arrangement and Airspeed on Contamination Control
Yi-Jen Huang, Swami Nath Maurya, Amir Reza Ansari Dezfoli
Key points
From the paper's conclusion- This study underscores the importance of blower arrangement and airspeed in optimizing clean-booth performance for efficient contamination control.
Abstract
Particle contamination remains a critical concern in medical and semiconductor industries, especially considering the COVID-19 pandemic, which has heightened focus on clean-booth systems. These booths, equipped with blower systems and high-efficiency filters, play an essential role in maintaining air quality by removing airborne particles. In this study, computational fluid dynamics simulations, using modified Navier–Stokes equations with a k-ε turbulence model coupled with a Lagrangian particle model, were employed to predict the performance of clean booths in controlling particle contamination. The effects of blower arrangement, exit size, and airspeed on particle concentration were evaluated. At an inlet airspeed of 0.4 m/s, the simulated booth-average particle number concentration first reached or fell below the reference threshold of 35,200 particles/m3 in approximately 12 and 30 s for the configurations with 100% and 65% blower coverage, respectively. The alternating-row configuration with 50% coverage did not reach the threshold within the simulated interval. At the common blower face velocity of 0.4 m/s, the configurations had different total supply airflow rates because their active inlet areas differed. The clearance results therefore reflect the combined effects of blower arrangement and total supply airflow. For the fully covered configuration, the booth-average concentration reached the threshold in approximately 7 s at 0.6 m/s and remained above it throughout the simulated interval at 0.1 m/s. These clearance times describe the booth-average concentration and do not establish ISO Class 6 compliance throughout the booth. The model’s accuracy was validated through experimental measurements using a SKY6000 particle counter, showing a maximum deviation of 12.5% in particle concentration at different locations. This study underscores the importance of blower arrangement and airspeed in optimizing clean-booth performance for efficient contamination control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Two Cyclonic Bioaerosol Samplers for Hospital Air Monitoring in a Calibrated Test Chamber Integrating Aerodynamics and Biological EndpointsIndoor Air · 2026
- Multi-Scale Computational Fluid Dynamics Investigation of Ventilation-Controlled and Gravity-Controlled Respiratory Aerosol Transport in an Office Environment: Implications for Heating, Ventilation, and Air Conditioning Design and Airborne Infection MitigationBuildings · 2026
- Investigation of airborne transmission and thermal comfort in a train cabin: Effects of air change rate and supply modeCase Studies in Thermal Engineering · 2025
- Evaluating Individual Infection Risk: The Interplay between Air Mixing Intensities and Occupant Dynamics.Environmental science & technology · 2026
- Modeling exhaled aerosol deposition in an impaction filter across clinically measured breath flowrates.Journal of breath research · 2026
- Experimental and Numerical Insights into Indoor Contaminant Transport and Ventilation Performance: A ReviewEng · 2026