Temporal Variability of Indoor Radon and Its Implications for Passive Measurement Strategies: A Pilot Case Study from Poland Based on 1-Month, 3-Month, and 12-Month Measurements
Sandra Nowak, Andrzej Chmiela, Małgorzata Wysocka
Key points
From the paper's conclusion- These findings indicate that the representativeness of short-term radon measurements depends on exposure duration and building-specific temporal variability.
Abstract
This pilot case study investigated how the duration of passive CR-39 (poly(allyl diglycol carbonate), PADC) measurements affects the representativeness of annual indoor radon concentration estimates. A one-year measurement campaign was conducted in a single-family residential building in the Upper Silesian Coal Basin (USCB), Poland. Passive radon monitors were deployed at three building levels (basement, ground floor, and first floor) for 1-month, 3-month, and 12-month exposure periods. Duplicate monitors were used, and measurements were performed according to an accredited laboratory procedure. The results were evaluated in terms of spatial, temporal, and seasonal variability, with shorter exposure measurements compared against independent 12-month measurements used as the annual reference. The highest radon concentrations and greatest temporal variability were observed in the basement. Monthly measurements showed pronounced short-term fluctuations, including elevated concentrations during a period of temporary building vacancy and limited ventilation. Seasonal patterns varied with both building level and exposure duration: 1-month measurements showed higher warm-season concentrations on the ground floor and first floor, whereas 3-month measurements showed a warm-season increase only on the ground floor. The mean absolute relative difference from the 12-month measurements was 46.3% for 1-month measurements and 13.2% for 3-month measurements. At the ground floor and first floor, the 3-month means were closer to the 12-month values than the 1-month means; the opposite was observed in the basement. When measurement uncertainty was considered, the mean 3-month concentrations were consistent with the independent 12-month results within the expanded uncertainty (k=2) at all three building levels. For 1-month measurements, this was the case only in the basement. The Rational Method assessment showed that the main criterion was satisfied by 27 of 36 monthly measurements and 9 of 12 quarterly measurements, with all cases in which the criterion was not satisfied occurring in the basement. These findings indicate that the representativeness of short-term radon measurements depends on exposure duration and building-specific temporal variability. Although limited to a single residential building, the results suggest that 3-month passive measurements may provide a more representative estimate of annual indoor radon concentrations than individual 1-month measurements under the investigated conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temporal variation of indoor 222Rn concentrations under contrasting room-opening conditions: A case study in Da Lat, Vietnam.Journal of environmental radioactivity · 2026
- Reconsidering indoor radon monitoring strategies in Romanian medical buildings: a data-driven perspective.Frontiers in public health · 2026
- Can radon measurements in five ground-floor rooms enable a good decision on absence/presence of elevated radon levels in a multi-room building?Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Methods for Estimation of Seasonal Indoor Radon Concentration Trend and Mean with Trend Decomposition and Distribution FittingApplied Sciences · 2026
- Cumulative and real-time performance of consumer-grade electronic radon monitors in a Canadian single-family home over three months.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Indoor radon concentrations in European kindergartens and other educational facilitiesEnvironment International · 2025