An Integrated Engineering Feasibility-Screening Framework for Electrification and Climate-Sensitive Retrofit of Existing Office Buildings
Darren Kelly, Akhtar Kalam, Shasha Wang
Key points
From the paper's conclusion- The framework identifies retrofit pathways that may proceed, require enabling works or further evidence, or be excluded before detailed design.
Abstract
Decarbonising existing office buildings requires retrofit pathways compatible with inherited electrical, hydronic, terminal-unit and spatial constraints. This study develops and applies a staged engineering feasibility-screening framework to two Canberra office buildings, integrating demand reduction, energy recovery, thermal storage, heat-pump electrification, electrical-demand assessment, annual energy and emissions, hydronic compatibility, spatial feasibility and future-weather sensitivity. At an electricity emissions factor of 0.500 kgCO2-e/kWh, air-source heat-pump (ASHP)/polyvalent electrification eliminated on-site gas combustion, changing annual operational emissions by −1.4% in Building A and +0.5% in Building B. Deterministic winter ASHP plant demands were 956.66 and 658.75 kW, respectively, requiring building-level electrical-capacity verification. Ground-source heat pumps reduced winter electrical demand but were excluded within the assessed site boundaries under the adopted borefield assumptions. At 55/45 °C, air-handling-unit heating-coil capacity fell to 71–79% and 71–75% of scheduled duty, respectively. Under a shared hourly weather-response screen, annual heating demand decreased by 24.2% and cooling demand increased by 30.6% in both buildings; identical proportional changes reflect common modelling assumptions. The framework identifies retrofit pathways that may proceed, require enabling works or further evidence, or be excluded before detailed design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accelerated Decarbonization of Non-Retrofitted Multifamily Buildings by Integrating Air-Source Heat Pumps in Existing Gas Boiler Systems: Techno-Economic and Environmental AnalysisEnergies · 2026
- A climate stress-testing framework for decarbonization pathways in existing buildingsJournal of Physics: Conference Series · 2026
- Building Stock Electricity Use and GHG Emissions in Greater Beirut: A GIS-Supported Assessment of 2010–2022 Trends and 2040 Scenarios for Sustainable Urban Energy PlanningSustainability · 2026
- Role of HVAC in building energy consumption: a critical reviewJournal of Thermal Analysis and Calorimetry · 2026
- Energy and carbon performance analysis of an operating room air conditioning system integrated with an exhaust air source heat pump using EnergyPlus : The case of A ntalyaEnvironmental Progress & Sustainable Energy · 2026
- Sensitivity Analysis of Input Data in Demand-Side Flexibility Assessments in Multi-Family Residential Buildings: An IDA ICE Simulation Case StudyE3S Web of Conferences · 2026