Journal of Physics: Conference Series

A climate stress-testing framework for decarbonization pathways in existing buildings

Davide Dell’Oro, Rossano Scoccia, Marco Imperadori

Key points

From the paper's conclusion
  • The framework supports building owners in assessing alternative decarbonization pathways when multiple building dimensions are considered, such as primary energy use, renewable energy integration, greenhouse gas (GHG) emission reduction, resilience to climate change, and the relationship between the building and the electrical grid.

Abstract

This study presents a Climate Stress-Testing Framework (CSTF) to identify and select pathways for decarbonizing existing buildings. The framework supports building owners in assessing alternative decarbonization pathways when multiple building dimensions are considered, such as primary energy use, renewable energy integration, greenhouse gas (GHG) emission reduction, resilience to climate change, and the relationship between the building and the electrical grid. The CSTF integrates these five dimensions into a unified methodology that evaluates pathway performance by comparing it with baseline performance in the current climate and by testing its robustness as climate changes under IPCC trajectories. The CSTF is applied to a case study, an existing building located in Padua. It identified and assessed three alternative decarbonization pathways: (S 1 ) adjustment of HVAC operating schedules; (S 2 ) integration of renewable energy; and (S 3 ) full heating electrification combined with PV integration. Renewable electricity procurement was included in all three pathways. A Building Performance Simulation (BPS) model was created for the baseline and all pathways. Each BPS model was simulated under current climate conditions and future climate projections (RCP4.5 and RCP8.5) for 2040 and 2080. The effectiveness assessment shows that the full electrification pathway (S3) can reduce primary energy use and total GHG emissions by 31% and 78%, respectively, compared to baseline, but may cause the building to hit grid constraint (DR = 1.17). Furthermore, the robustness assessment shows that the pathways sustain decarbonization performance under climate-change stress testing and reveal previously unseen limitations. All pathways exposed the building to a significant increase in cooling-related discomfort, indicating a progressive deterioration of HVAC cooling performance under climate change. The CSTF methodology shows that incorporating additional performance dimensions and climate stress testing into decarbonization planning can significantly alter pathway selection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers