Destructive-Test Evaluation of Reinforced Galvanic Isolation and Solid-State Overcurrent Protection in Automotive High-Voltage Subsystems
Mihai-Ionuț Dumitru, Dumitru-Daniel Bonciog, Adriana Berdich, Valentin-Ioan Maranescu, Mircea Bancila
Key points
From the paper's conclusion- The results are exploratory, given the small samples, and support several recommendations for HV safety-validation testing.
Abstract
Reinforced galvanic isolation and solid-state overcurrent protection (eFuse) are critical safety barriers in automotive high-voltage (HV) power electronics, yet they are rarely evaluated together. This paper reports destructive robustness tests of both barriers on hardware of the same automotive HV subsystem, at up to 850 VDC, as a complement to IEC 60747-17 certification. For the isolation barrier, 39 samples from two 5 kVrms-rated digital-isolator families (reinforced and basic insulation) were stressed with continuous DC/AC voltage. Except for two samples tested without energy limitation, which failed catastrophically, all samples passed a 1.5 kV/60 s HIPOT test and read above the 500 MΩ range of the multimeter, even when visibly punctured. For the overcurrent barrier, five eFuse power stages were tested in an 850 VDC capacitor-fed short circuit and at 10–360 VDC with a 120 A current limit. All five failed open; in the 850 VDC test the current was interrupted within 0.5 ms (limit 1.2 s), and no thermal event occurred outside the enclosure within the 12 s observation window. The results are exploratory, given the small samples, and support several recommendations for HV safety-validation testing. After every eFuse fault, the HV–LV isolation of the subsystem remained intact.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive diagnostics of DC Interruption Process of Pure-Water Arc Discharge under High-Pressure ConditionsJournal of Physics D: Applied Physics · 2026
- Short‐Circuit Current Behavior in High‐Voltage Disconnectors: A Critical Review of Analytical, Numerical, and Experimental InvestigationsRadio Science · 2026
- Transient Inrush Current Analysis and Suppression for Grid-Forming Converters Under Grid FaultsIEEE Transactions on Industrial Electronics · 2025
- Dual-threshold graded desaturation protection for IGBTs in VSC-HVDC converter valve submodulesJournal of Engineering and Applied Science · 2026
- Experimental Study of Non-Design-Basis Electromagnetic Interference and the Risk of False Operation of Relay Protection at a 500 kV SubstationApplied Sciences · 2026
- Investigation into Combined AC–DC Insulation Stress Evolution Mechanism and Combined Withstand Voltage Test Method for 40.5 kV Capacitor Bank Circuit Breaker BreaksEnergies · 2026