Expert-Informed Engineering Requirements for Distributed Soil-Moisture Sensing in Plastic Water-Pipe Leak Monitoring
Benjamin Jonathan Maij, Nirvana Meratnia, Marcel Louis Meli
Key points
From the paper's conclusion- The requirements are provisional design inputs; technical feasibility and final acceptance criteria require laboratory, field, and stakeholder validation.
Abstract
Leak detection in underground drinking-water networks is especially difficult in plastic pipes because leak-generated acoustic and vibration signals attenuate strongly. This study investigates the concept of distributed soil-moisture monitoring as a potential complementary early-warning approach and derives stakeholder requirements for future system development. An expert questionnaire was distributed by email to 90 water-supply utilities in the Swiss cantons of Thurgau, Zurich, and Aargau. Fifty-five submissions were received (61.1% relative to invitations), of which 52 included consent for research use and were analysed (57.8% of invitations). Item-specific denominators, Wilson 95% confidence intervals, and exploratory exact and non-parametric subgroup tests were used. Current practice was dominated by acoustic methods (48/52) and baseline-consumption monitoring (41/52). Among valid quantitative answers, 29/47 respondents expected detection at or below 20 L/h (61.7%, 95% CI 47.4–74.2%), 44/46 preferred at least daily sampling (95.7%, 85.5–98.8%), 41/45 selected a price at or below EUR 20/m (91.1%, 79.3–96.5%), 36/46 specified a false-alarm tolerance of no more than one per year (78.3%, 64.4–87.7%), and 39/44 specified a missed-leak tolerance of no more than 5% (88.6%, 76.0–95.0%). These cumulative proportions include more demanding response categories and do not establish acceptance of performance exactly at each boundary. Experience-group comparisons yielded no statistically significant differences after Holm correction. The contribution is a traceable, uncertainty-aware requirement specification linked to engineering relationships and verification planning for power, spacing, latency, cost, false alarms, and missed detections. Limited precision, regional recruitment, and unfamiliarity with the monitoring approach constrain interpretation. The requirements are provisional design inputs; technical feasibility and final acceptance criteria require laboratory, field, and stakeholder validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Smart Leak Detection in Water Distribution Networks: A Systematic Review and D-A-T TaxonomyWater · 2026
- Progressive segment-wise estimation for multi-leak localization in water distribution networksMeasurement Science and Technology · 2026
- Sensor placement for real-life water distribution networks, ensuring observability under uncertaintiesarXiv · 2026
- Edge-intelligent leak detection in water distribution systems using CatBoost: A sustainable solution for reducing infrastructure lossesClean Energy Science and Technology · 2025
- Which uncertainties matter? Global sensitivity analysis of model-based and data-driven leakage detection methods via sparse-grid stochastic collocation.Water research · 2026
- Multiphysics monitoring of leakage-induced soil wetting and localized deformation around buried water pipelines: a physical model study with implications for mining-affected areasFrontiers in Earth Science · 2026