Which uncertainties matter? Global sensitivity analysis of model-based and data-driven leakage detection methods via sparse-grid stochastic collocation.
Ella Steins, Johannes Koslowski, Andrea Cominola
Chair of Digital Water Systems, Technische Universität Berlin, Berlin 10623, Germany; Einstein Center Digital Future, Berlin 10117, Germany. Electronic address: steins@tu-berlin.de. · Kompetenzzentrum Wasser Berlin, Berlin 10825, Germany. Electronic address: johannes.koslowski@kompetenz-wasser.de.
Key points
From the paper's conclusion- To address this gap, we conduct a variance-based global sensitivity analysis of the detection performance of two state-of-the-art leakage detection methods, data-driven and model-based, under uncertainties in the number of pressure sensors, sensor accuracy, hydraulic model parameters, and a method hyperparameter.
Abstract
Leakages in water distribution networks cause water loss globally, jeopardize water quality, and increase energy consumption for water supply. While numerous software-based detection methods to enable prompt leakage detection have been proposed in the literature, most are developed using synthetic data that fails to represent the range of errors and operating conditions encountered in practice. To address this gap, we conduct a variance-based global sensitivity analysis of the detection performance of two state-of-the-art leakage detection methods, data-driven and model-based, under uncertainties in the number of pressure sensors, sensor accuracy, hydraulic model parameters, and a method hyperparameter. To keep the analysis tractable, we use sparse-grid stochastic collocation, reducing the number of model evaluations by orders of magnitude relative to Monte Carlo. We assess convergence, robustness, and credibility of the estimates. In this study, sensor number and measurement accuracy dominate detection performance for both methods, whereas hydraulic parameters and the detection threshold are secondary; finer rankings among the remaining inputs differ by leakage type and method but often fall within the estimated uncertainty. The two methods fail in different regimes, motivating hybrid strategies that combine their strengths.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensor placement for real-life water distribution networks, ensuring observability under uncertaintiesarXiv · 2026
- Smart Leak Detection in Water Distribution Networks: A Systematic Review and D-A-T TaxonomyWater · 2026
- A multivariate statistical framework for detection, classification and pre-localization of anomalies in water distribution networksExpert Systems with Applications · 2026
- Progressive segment-wise estimation for multi-leak localization in water distribution networksMeasurement Science and Technology · 2026
- Construction of a leak detection and pressure regulation system for municipal water distribution networks integrating digital twin technologyScientific Reports · 2026