Dominant-Pole-Based Tuning Criterion for Coordinated Needle–Deflector Control in Pelton Turbines for Hybrid Wind–Hydro Power Systems
Silenys Restrepo-Oñate, Guillermo Martínez-Lucas, José Ignacio Sarasúa
Key points
From the paper's conclusion- Simulations of a hybrid wind–hydro power system under variable wind generation further show that the proposed controller can substantially increase the admissible wind-power penetration while maintaining adequate frequency regulation.
Abstract
The increasing penetration of converter-interfaced renewable generation in hybrid wind–hydro power systems strengthens the frequency-regulation requirements imposed on hydropower plants, particularly in isolated power systems. In Pelton turbine installations, the deflector, traditionally used as a safety device, has recently been incorporated as an active element for frequency regulation. By rapidly modifying the fraction of the jet reaching the runner without immediately changing the penstock flow, the deflector mitigates the influence of pressure-wave dynamics on the plant response, although its operation entails hydraulic-energy losses due to jet diversion. This study proposes a modal-analysis-based tuning criterion for a coordinated needle–deflector control scheme (CCS) with a proportional-integral controller. In this configuration, the proportional action is assigned to the deflector and the integral action to the needle. The proposed method combines an eigenvalue sensitivity–speed assessment based on modal settling time and eigenvalue sensitivity with characteristic-polynomial coefficient matching to derive closed-form expressions for the controller gains. Root-locus trajectories and modal properties confirm the prescribed eigenvalue structure and demonstrate the advantages of the proposed tuning criterion over the conventional Paynter criterion. The resulting controller is evaluated using a detailed nonlinear elastic model based on one hydraulic branch of the Coca Codo Sinclair Hydropower Plant in Ecuador. Under a sudden increase in demand, the CCS improves the frequency nadir, reduces power oscillations, and accelerates frequency recovery compared with the conventional needle control scheme. Simulations of a hybrid wind–hydro power system under variable wind generation further show that the proposed controller can substantially increase the admissible wind-power penetration while maintaining adequate frequency regulation. For the analyzed scenario, the additional wind energy accommodated by the coordinated scheme exceeds the hydraulic-energy cost associated with jet diversion, indicating a favorable trade-off between frequency regulation performance, renewable-energy integration, and hydraulic losses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mitigating Low Pressure in Draft Tubes of Pumped-Storage Units by Installing Tailwater Connection Pipes Under Successive Load Rejection Conditions: Mechanism and Effectiveness AnalysisWater · 2026
- The regulation and control process of large hydroelectric generating units under PFR-AGC coordinationEngineering Research Express · 2026
- Extending the Stable Operating Range of Francis Turbines Through Variable-Speed Control: A Numerical StudyJournal of Physics: Conference Series · 2026
- Integrated evaluation of geometric and operating parameters on H-Darrieus hydrokinetic turbine performance and structural responseJournal of the Brazilian Society of Mechanical Sciences and Engineering · 2026
- Research on Automatic Power Generation Control and Primary Frequency Regulation Parameter Characteristics of Hydropower UnitsWater · 2025
- Integrated numerical–physical modeling for optimizing riverbed dredging in Mixed Pumped-Storage Power Stations: a case study of Lianghekou projectScientific Reports · 2026