Weather-Driven PV-BESS Voltage Control for Radial Distribution Feeders
Mohammed Esmat Yousif, Mutlu Yilmaz
Key points
From the paper's conclusion- This work also includes FACVC component analysis, multi-placement IEEE 33-bus validation, a CIGRE MV pandapower benchmark, surrogate-versus-AC error quantification, descriptive and paired inferential statistical analysis, and a proxy economic comparison.
Abstract
The integration of photovoltaic (PV) systems in distribution feeders creates voltage-control challenges because PV generation changes with irradiance, temperature, and wind speed. This paper presents the Feeder-Aware Coordinated Voltage Control (FACVC) method for radial PV-BESS distribution feeders. Weather-driven denotes the traceable conversion of meteorological inputs into PV power followed by feeder-voltage evaluation, rather than a new electrical-device category. The test environment is a Python workflow using our PV power conversion program and pandapower AC power flow for the verified IEEE 33-bus operating cases; reduced custom and benchmark-inspired feeders are retained for screening controller behavior. FACVC uses load condition, available PV generation, feeder sensitivity coefficients, battery state of charge, and inverter reactive-power limits to coordinate battery charging/discharging and reactive-power support. It is compared with No Control, Rule-Based Control, Random Control, an SOC-constrained Volt-VAR-BESS droop comparator, and an implementation-specific PPO-RL benchmark. In the verified IEEE 33-bus results, FACVC reduced the average voltage-violation count from 171.67 under No Control to 79.67, a 53.6% reduction, and increased average voltage from 0.9468 pu to 0.9630 pu. This work also includes FACVC component analysis, multi-placement IEEE 33-bus validation, a CIGRE MV pandapower benchmark, surrogate-versus-AC error quantification, descriptive and paired inferential statistical analysis, and a proxy economic comparison. The simulation results show that FACVC improves voltage security through coordinated active and reactive support, although control-support costs can increase on feeders that are already within allowable ranges. The study therefore presents FACVC as a reproducible deterministic voltage-support benchmark.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive weighted multi-objective battery storage optimization in virtual power plant-controlled networks integrating electric vehicles and photovoltaicsApplied Energy · 2026
- Deep Reinforcement Learning-Based Voltage-Var Control for Active Distribution Networks Using GAT-SimAMEnergies · 2026
- Machine learning-driven PV forecasting and coordinated PV–BESS dispatch for optimizing distribution grid performance under high EV penetrationEnergy Conversion and Management X · 2025
- A residential virtual power plant of electric vehicles and batteries for a resilient grid during normal and extreme weatherJournal of Energy Storage · 2026
- ADBO-Optimized Smart Inverter Integration of PV/BESS for Incremental EV Charging Capacity Without Further Voltage Degradation on a Gaborone-Oriented IEEE 69-Bus Surrogate FeederEng · 2026
- Capacity and Operation Planning of Distributed Photovoltaic and Energy Storage with Screening-Based Site Assessment and Coordinated Reactive Power Compensation in Distribution NetworksEnergies · 2026