Full-Scale Shear Testing of a Reversible Timber–Carbon-Reinforced Concrete Wall System Using Embedded Transport Anchors as Shear Connectors
Mario Stelzmann, Lukas Steffen, Thomas Klink, Klaus Holschemacher
Leipzig University of Applied Sciences
Key points
From the paper's conclusion- The results demonstrate the feasibility of the investigated reversible timber–CRC connection concept for transferring in-plane shear forces in the tested configuration, but further tests are required before general design recommendations can be derived.
Abstract
This paper presents an experimental investigation of a demountable hybrid timber–carbon-reinforced concrete (CRC) wall system with a reversible mechanical connection detail based on embedded transport anchors, screwed steel angle brackets, and full-thread screws. The study addresses a wall concept in which a thin externally mounted CRC plate contributes to lateral load transfer through discrete reversible connection points rather than through a bonded or cast-in-place composite interface. Four full-scale wall specimens were tested under horizontal shear loading and a nominal vertical preload of 92kN in an adapted in-plane shear test arrangement. The maximum horizontal loads ranged from 19.7 to 22.7kN, with a mean value of 21.2kN and a coefficient of variation of 5.9%. For the three specimens with complete displacement records, the head displacement at maximum load ranged from 33.7 to 45.8mm. The initial wall stiffness K0.05−0.15 ranged from 1.93 to 2.80kN/mm, whereas the stiffness evaluated between 0.2Fmax and 0.4Fmax ranged from 0.52 to 0.67kN/mm. Normalized to the reference width of the tested configuration, the maximum horizontal load was 15.8 to 18.2kN/m. Damage initiated locally in the CRC anchorage zones, especially at the corner anchors, and progressed from first cracking to local concrete spalling. The governing failure mode was local concrete failure in the anchorage zones, accompanied by deformation of the steel angle brackets, while no critical damage was observed in the timber joints. The results demonstrate the feasibility of the investigated reversible timber–CRC connection concept for transferring in-plane shear forces in the tested configuration, but further tests are required before general design recommendations can be derived.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- JOINTS: Classification and analytical evaluation of detachable dry connections for reusable concrete elementsarXiv · 2026
- Numerical Simulations of 5‐Story Building Using Wood Light‐Frame Shear Walls and Post‐Tensioned Cross‐Laminated Timber Rocking Wall Dual SystemsEarthquake Engineering & Structural Dynamics · 2026
- Mortise-and-Tenon Connections for Rebar-Free ECC Beams: Experimental and Numerical Investigation.Materials (Basel, Switzerland) · 2026
- Bolted timber joints with corrugated versus flat steel plates and CFRP reinforcementProceedings of the Institution of Civil Engineers - Structures and Buildings · 2026
- Integrating CFRP U-Wrapping and Spike Anchors in the Applications of Flexural Strengthening of RC BeamsCivil and Environmental Engineering · 2026
- Shear capacity modeling for I- and H-shaped steel reinforced recycled aggregate concrete beams: A short communication study based on modified compression field theoryAIP Advances · 2026