Mortise-and-Tenon Connections for Rebar-Free ECC Beams: Experimental and Numerical Investigation.
Manfang Lin, Lingzhi Li, Yunqi Jiang
College of Civil Engineering, Tongji University, Shanghai 200092, China.
Key points
From the paper's conclusion- The results show that mid-span connections strengthened with one and two CFRP layers increased the average peak load by approximately 20% and 47%, respectively, compared to unstrengthened specimens.
Abstract
Engineered cementitious composites (ECCs) combine high tensile ductility, multiple cracking, and sustained post-cracking load transfer, making rebar-free structural members feasible. However, eliminating longitudinal reinforcement also removes the conventional load-transfer path across prefabricated components, making reliable connections a key obstacle to their wider application. Mortise-and-tenon joints offer a potential solution through geometric interlocking and local strengthening. This study experimentally investigated one monolithic cast beam and 19 mortise-and-tenon-connected ECC beams considering ECC strength, joint geometry, CFRP strengthening, loading direction, and connection location. A finite-element model was further developed to capture mortise-and-tenon contact, interface degradation, and CFRP strengthening. The results show that mid-span connections strengthened with one and two CFRP layers increased the average peak load by approximately 20% and 47%, respectively, compared to unstrengthened specimens. However, excessive local strengthening may shift damage toward the CFRP termination. Straight joints exhibited smaller loading-direction differences in peak load (1.5-7.4%) than dovetail joints (15.4-21.7%). Moving straight connections from mid-span to the shear span allowed specimens to retain approximately 89-94% of the monolithic reference peak load and 74-90% of its peak deflection. These findings provide a basis for efficient connection design in prefabricated rebar-free ECC structures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flexural Behavior of Rebar-Free 3D-Printed ECC Beams with Mortise-and-Tenon ConnectionsBuildings · 2026
- Enhancing the performance of reinforced concrete structures using engineered cementitious composites: Mechanisms, effectiveness, and design implicationsJournal of Building Engineering · 2026
- Seismic performance of reinforced concrete beam column joints strengthened with ECC shellsScientific Reports · 2026
- Retrofitting damaged subway station columns with CFRP grid-reinforced ECC jackets for improved seismic performanceEngineering Structures · 2025
- Flexural Capacity Calculation Method for Pre-Damaged RC Beam-Column Joints Strengthened with High-Strength Steel Strand Mesh-Reinforced ECC.Materials (Basel, Switzerland) · 2026
- Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beamsScientific Reports · 2026