Audrey Rah, Yuhua Chen
Early-stage stroke rehabilitation increasingly incorporates virtual reality (VR) systems to provide interactive motor training and positive reinforcement. However, the minimal voluntary plantar pressure activations generated during early recovery are often below the detection limits of conventional pressure-sensing platforms, restricting timely feedback. This study quantitatively evaluates the detectability of low-amplitude plantar micro-intent signals under varying sensor resolution and adaptive threshold conditions. Publicly available plantar pressure recordings from the PhysioNet Center for Verification and Evaluation of Stroke (CVES) database were used as physiological baseline signals. Micro-intent was modeled as short-duration half-sine pressure pulses with systematically varied amplitudes and integrated into low-load baseline segments. Sensor resolution was represented through controlled noise modeling to emulate low-, medium-, and high-resolution sensing scenarios. A sliding-window adaptive threshold detector was evaluated across multiple amplitudes and sensitivity stages. The detection probability, false positive rate, and minimum detectable amplitude (defined as ≥80% detection probability) were quantified. The results show that detection probability increases with signal amplitude and shifts toward lower amplitudes with improved sensor resolution and more sensitive threshold configurations. Higher-resolution sensing reduced the minimum detectable amplitude, while adaptive thresholding enabled earlier detection of weak plantar activations without substantial increases in false positives. These findings provide quantitative design guidance for pressure-sensing VR rehabilitation systems targeting early-stage motor recovery.