Development and field validation of a large-volume bag-based whole-blood collection method in donor dairy cows.
Filippo Rigo, Luca Panozzo, Giacomo Catarin, Margherita Soncin, Antonio Barberio, Flaviana Gottardo
Department of Animal Medicine, Production and Health, University of Padua, Padua, Italy. · Istituto Zooprofilattico Sperimentale delle Venezie, Padua, Italy.
Key points
From the paper's conclusion- In conclusion, this large-volume bag-based protocol proved feasible for whole-blood collection in donor dairy cows under field conditions and may provide a practical upstream basis for subsequent laboratory applications and downstream processing workflows.
Abstract
Obtaining sterile anticoagulated whole-blood units is a key prerequisite for downstream laboratory and clinical applications involving blood-derived products. In bovine medicine, however, published information on blood collection into bags is mainly embedded in transfusion-oriented references or broader downstream studies, while formal validation of donor-oriented collection methods remains limited. The aim of this study was to develop and field-validate a large-volume bag-based method for whole-blood collection in donor dairy cows under commercial farm conditions. Whole-blood collections were performed in clinically healthy donor dairy cows using a jugular venipuncture protocol that was progressively refined during field validation. A true sequential multi-bag setup, enabled by extension tubing and a perforable connection device, was introduced on 24 October 2022. Protocol validation was based primarily on procedural success, defined as a bacteriologically negative blood unit with a collected volume of at least 400 mL per bag. A total of 294 procedures were included. Overall, 228/294 procedures (77.6%) were classified as successful, 48/294 (16.3%) as suboptimal, and 18/294 (6.1%) as failed. The median collected volume per procedure was 410 mL (IQR 400-430; range 124.5-1,280 mL). Overall, 276/294 collections (93.9%) were bacteriologically negative. Within the single-bag phase, later collection dates were associated with a lower probability of bacteriological positivity, supporting a learning-curve effect on microbiological reliability. Later implementation of the sequential multi-bag setup was associated with a higher total volume per procedure, without an apparent loss of microbiological safety. In conclusion, this large-volume bag-based protocol proved feasible for whole-blood collection in donor dairy cows under field conditions and may provide a practical upstream basis for subsequent laboratory applications and downstream processing workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of microbiological testing protocols on discard rates in donor human milk with a focus on Bacillus cereus.Frontiers in microbiology · 2026
- Platelet-Based Blood Products in Bovine and Equine Medicine: A Systematic Scoping Review of Blood Collection, Preparation Methods, and Reporting Completeness.Veterinary sciences · 2026
- Agreement of a Handheld Glucose Meter with Laboratory Serum Glucose Measurements in Dairy CowsDairy · 2026
- Whole-blood metabolic biomarkers improve detection of subclinical ketosis in postpartum grazing dairy cows.JDS communications · 2026
- Animal Welfare Assessment in Cattle Breeding in the Natural Savannah of the Colombian Orinoquia.Veterinary medicine international · 2026
- Immunological and bacteriological quality of bovine colostrum, passive transfer of immunity, and associated maternal, colostral and management-related risk factors in dairy calves in northern Algeria.Veterinaria italiana · 2026