Diagnostic performance of Vcheck NT-proBNP and cardiac troponin I assays for detection of dilated cardiomyopathy in Doberman Pinschers.
Helena Driessen, Jana Friederich, Gerhard Wess
LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Faculty of Veterinary Medicine, Ludwig-Maximilians-University, Munich, Germany.
Key points
From the paper's conclusion- NT-proBNP and cTnI concentrations were significantly higher in dogs with DCM than in healthy controls. For NT-proBNP measured with Vcheck, a cutoff of ≥580 pmol/L yielded 76.6% sensitivity and 83.1% specificity (AUC 0.845). For cTnI measured with Vcheck, a cutoff of ≥0.21 ng/mL achieved 71.0% sensitivity and 78.3% specificity (AUC 0.809). The IDEXX cTnI assay showed higher diagnostic accuracy, particularly in early-stage disease, including "last normal" dogs. Combining both Vcheck biomarkers increased sensitivity and overall diagnostic performance (AUC 0.886), but specificity was reduced and performance remained lower than that of IDEXX cTnI alone.
Abstract
BACKGROUND: Dilated cardiomyopathy (DCM) is a common hereditary cardiac disease in Doberman Pinschers. Early myocardial changes can be detected using cardiac biomarkers such as N-terminal pro-B-type natriuretic peptide (NT-proBNP) and cardiac troponin I (cTnI). The Vcheck V200 (Bionote) is a point-of-care immunofluorescence-based assay for in-clinic measurement of these markers. OBJECTIVE: To evaluate the diagnostic performance of NT-proBNP and cTnI measured with the Vcheck V200 point-of-care assays for detecting different stages of DCM in Doberman Pinschers and to compare Vcheck cTnI results with those obtained using a laboratory-based IDEXX cTnI assay. ANIMALS: A total of 453 serum samples from 345 privately owned, purebred Doberman Pinschers in Germany were analyzed. Dogs were clinically classified into five stages (A, last normal, B1, B2, and C) based on echocardiographic and electrocardiographic findings. METHODS: This prospective longitudinal study included physical examination, echocardiography, 24-h Holter monitoring, and biomarker analysis. NT-proBNP and cTnI concentrations were measured using the Vcheck V200 assay. In a subset of 358 samples, cTnI concentrations were additionally measured using the IDEXX assay. Diagnostic performance was evaluated using receiver operating characteristic curve analysis, and agreement between cTnI assays was assessed using Bland-Altman analysis. RESULTS: NT-proBNP and cTnI concentrations were significantly higher in dogs with DCM than in healthy controls. For NT-proBNP measured with Vcheck, a cutoff of ≥580 pmol/L yielded 76.6% sensitivity and 83.1% specificity (AUC 0.845). For cTnI measured with Vcheck, a cutoff of ≥0.21 ng/mL achieved 71.0% sensitivity and 78.3% specificity (AUC 0.809). The IDEXX cTnI assay showed higher diagnostic accuracy, particularly in early-stage disease, including "last normal" dogs. Combining both Vcheck biomarkers increased sensitivity and overall diagnostic performance (AUC 0.886), but specificity was reduced and performance remained lower than that of IDEXX cTnI alone. CONCLUSION AND CLINICAL IMPORTANCE: The Vcheck V200 provides a practical and accessible tool for in-clinic biomarker assessment in Doberman Pinschers at risk for DCM. While Vcheck NT-proBNP and cTnI may help identify dogs requiring further cardiac evaluation, the laboratory-based IDEXX cTnI assay showed higher diagnostic accuracy, especially for early-stage detection. Dogs exceeding these biomarker thresholds should undergo comprehensive cardiac evaluation, including echocardiography and 24-h Holter monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analytical agreement of a multiparametric, fully quantitative fluorescent immunoassay analyser (Vcheck) with commercial laboratory assays for NT‑proBNP and cardiac troponin‑I in dogs and cats.Veterinary journal (London, England : 1997) · 2026
- Exploratory Evaluation of Cardiac Fatty Acid-Binding Protein (H-FABP), Troponin I, NT-proBNP, Echocardiography, and Holter Monitoring for the Assessment of Doxorubicin-Induced Cardiac Damage in Dogs.Veterinary sciences · 2026
- Point-of-care troponin I assay has acceptable performance detecting clinically important canine myocardial injury but reduced precision at low concentrations.American journal of veterinary research · 2026
- Analytical validation and clinical evaluation of a high-sensitivity cardiac troponin I immunoassay for use in catsPLoS ONE · 2026
- Reduced Plasma Cardiac Myosin-Binding Protein-C Concentrations in Cats with Hypertrophic Cardiomyopathy: Evidence from Chronic, Treated Disease.Animals : an open access journal from MDPI · 2026
- Global longitudinal strain assessment of systolic dysfunction in Doberman Pinschers with ventricular arrhythmias and normal echocardiographic measurements.Journal of veterinary internal medicine · 2026