Inertial measurement unit-based characterization of gait patterns in Asian elephants: clinically sound elephants and elephants with gait abnormalities.
Siripat Khammesri, Kittichai Wantanajittikul, Kittikul Namwongprom, Narueporn Kittisirikul, Chatchote Thitaram, Niyada Thitaram, Janine L Brown, Siriphan Kongsawasdi
Department of Physical Therapy, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand. · Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
Key points
From the paper's conclusion- Ten clinically sound elephants were used to describe preliminary observed values, while four elephants with clinically identified abnormal gait patterns were evaluated individually through descriptive case comparison.
Abstract
Objective gait assessment is important for detecting locomotor abnormalities in Asian elephants, but clinical interpretation remains constrained by the limited availability of species-specific gait data from clinically sound elephants and the practical constraints of conventional laboratory-based gait analysis. This study aimed to report preliminary observed values for IMU-derived gait parameters in clinically sound Asian elephants and to explore their application for characterizing abnormal gait patterns. Four inertial measurement unit sensors were attached bilaterally over the humerus and femur to record gait data during straight-line walking at a controlled speed. Ten clinically sound elephants were used to describe preliminary observed values, while four elephants with clinically identified abnormal gait patterns were evaluated individually through descriptive case comparison. Temporospatial parameters and duty factor (DF) were analyzed to characterize stance allocation, while cross-correlation coefficients (COF) of left-right vertical displacement waveforms were used to quantify bilateral vertical movement similarity. In clinically sound elephants, stride timing was generally comparable between sides, whereas stance-related parameters showed a consistent side-related pattern. Descriptive comparison with abnormal cases showed case-specific alterations in DF and COF. These findings provide preliminary observed values for IMU-based gait assessment in Asian elephants and support the complementary descriptive use of these parameters for characterizing stance allocation and bilateral vertical movement similarity. Larger clinical datasets are needed to establish clinically relevant thresholds and strengthen their clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- IMU-based gait analysis methods: a systematic review of techniques for different body locationsFrontiers in Sports and Active Living · 2026
- Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators.Journal of the American Veterinary Medical Association · 2026
- IMU-based gait analysis methods: a systematic review of techniques for different body locations.Frontiers in sports and active living · 2026
- A Comparative Review and Benchmarking Evaluation of Step Detection Methods for Longitudinal Gait Assessment.Sensors (Basel, Switzerland) · 2026
- Validation of IMU-Based Insoles (LUBU) for the Estimation of Gait Spatio-Temporal Parameters.Sensors (Basel, Switzerland) · 2026
- Pair-consistent step-length and gait-asymmetry estimation from two thigh-mounted inertial sensorsFrontiers in Bioengineering and Biotechnology · 2026