Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators.
Jenna L McPeek, Adrianne Caudill, Emma Adam, Sophia Carattini, Olivia Jacob, Allen E Page
1Maxwell H. Gluck Equine Research Center, Martin-Gatton College of Agriculture, Food and Environment, University of Kentucky, Lexington, KY. · 2Dr. Bing Zhang Department of Statistics, College of Arts and Sciences, University of Kentucky, Lexington, KY.
Key points
From the paper's conclusion- Despite inherent horse variability and minor differences in testing conditions, objective gait evaluation systems consistently produced measurements indicating moderate to excellent reliability and low measurement error.
Abstract
OBJECTIVE: To evaluate the intrasystem reliability of an AI-based smartphone application Sleip (AI-SPA), the inertial measurement unit (IMU) system Equinosis Q Lameness Locator (LL), and the IMU system Equisym (ES) across 2 different hard surfaces and to assess the interoperator reliability for the 2 IMU systems. METHODS: 8 mixed-breed research horses, aged 4 to 12 years, with varying degrees of gait asymmetries were utilized. To assess intrasystem reliability, horses were in-hand, straight-line trotted on either epoxy-coated concrete or rubber-coated concrete. Three trials were performed for LL and ES, while 6 concurrent trials were performed for AI-SPA. Interoperator reliability was assessed with 4 operators on the rubber-coated concrete only. Intraclass correlation coefficients and SE of measurements were calculated for 4 outcome parameters common to all systems as well as a variety of system-specific outcome parameters for LL and ES. RESULTS: Nearly all intraclass correlation coefficients indicated moderate to excellent intrasystem reliability (> 0.50) across the 3 systems (AI-SPA, 0.40 to 0.85; LL, 0.73 to 0.94; ES, 0.44 to 0.99) and were comparable between surfaces. Interoperator reliability was moderate to excellent for both LL (0.72 to 0.92) and ES (0.73 to 0.96). Standard error of measurement values remained relatively stable across study conditions. CONCLUSIONS: Despite inherent horse variability and minor differences in testing conditions, objective gait evaluation systems consistently produced measurements indicating moderate to excellent reliability and low measurement error. CLINICAL RELEVANCE: These findings indicate that observed changes in system output are unlikely to be impacted by operator or hard-surface effects, supporting clinical reliability of these systems in routine practice when utilizing manufacturers' instructions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a novel instrumented hoof boot with pressure sensors using force plate gait kinetics in horses at walk and trot.Equine veterinary journal · 2026
- Inertial measurement unit-based characterization of gait patterns in Asian elephants: clinically sound elephants and elephants with gait abnormalities.Frontiers in veterinary science · 2026
- Discipline-associated locomotor coordination and asymmetry patterns in trained Quarter Horses: a cross-sectional study.BMC veterinary research · 2026
- Validation of a handheld smartphone markerless method for quantifying thoracolumbar flexion-extension range of motion in horses at trot.Equine veterinary journal · 2026
- Inter-week Variation in Movement Asymmetry at Trot in Cavalry Horses in Training.Journal of equine veterinary science · 2026
- Context-aware machine learning for lameness side and severity prediction in trotting horses: A proof-of-concept study.Equine veterinary journal · 2026