Frontiers in surgery

Construction of a quality evaluation index system for waterless surgical hand antisepsis in operating rooms.

Songping Yang, Xi Yuan, Xuequn Yin, Wenjuan Zhou, Huixian Zhou, Li Miao, Guo Zhang, Xinmei Zhang

Department of Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China.

Key points

From the paper's conclusion
  • Conclusion This study produced a consensus-based and hierarchically weighted quality evaluation index system for waterless surgical hand antisepsis.

Abstract

OBJECTIVE: To develop and obtain expert consensus on a quality evaluation index system for waterless surgical hand antisepsis in operating rooms and to assign hierarchical weights to the finalized indicators. METHODS: Guided by the Donabedian structure-process-outcome model, candidate indicators were generated through a structured literature review and semi-structured interviews. A three-round expert consultation was conducted: Rounds 1 and 2 were used to screen and refine indicators, and Round 3 was used for AHP-based pairwise weighting. Twenty-two eligible experts received the Round-1 questionnaire; 20 returned valid questionnaires and constituted the panel retained for Rounds 2 and 3, in which all 20 responded. Expert authority was assessed using Cr = (Ca + Cs)/2. In Round 3, individual expert authority coefficients were normalized to obtain expert-specific weights, and pairwise judgments were aggregated using a weighted geometric mean before AHP weight calculation and consistency testing. RESULTS: The valid response rates were 90.9% (20/22), 100% (20/20), and 100% (20/20) in Rounds 1, 2, and 3, respectively. The panel mean expert authority coefficients (Cr) were 0.883, 0.895, and 0.900. Kendall's coefficients of concordance for the two indicator-screening rounds were 0.242 and 0.334, respectively (both P < 0.001), while coefficients of variation decreased from 0.07-0.20 to 0.05-0.18. The aggregated AHP group judgment matrices satisfied the predefined consistency criterion (CR < 0.10). The final system comprised three first-level, nine second-level, and 28 third-level indicators. The global weights of the first-level domains were structure 0.1762, process 0.4123, and outcome 0.4115. CONCLUSION: This study produced a consensus-based and hierarchically weighted quality evaluation index system for waterless surgical hand antisepsis. The framework may support standardized quality assessment and future quality-improvement work; however, the present study establishes expert consensus and relative priorities rather than clinical effectiveness, psychometric reliability, or causal effects. Multicenter clinical validation is required before broad implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers