A comparative evaluation of deep learning models for the classification of encoded splice-junction sequences.
Yogesh Kumar, Inderpreet Kaur, Nandini Modi, Priya Bhardwaj, Jaeyoung Choi, Muhammad Fazal Ijaz
Department of Computer Science and Engineering, School of Technology, Pandit Deendayal Energy University, Gandhinagar, India. · Department of Computer Applications, Chandigarh Group of Colleges, Mohali, India.
Key points
From the paper's conclusion- The highest held-out test accuracy (96.87%) was obtained with the Custom CNN from among the configurations that were saved. The MLP Mixer was the most highly accurate model during training (99.90%), but the model did not perform as well on the validation set (93.33%) or held-out test set (93.73%), suggesting some in-sample fitting. Model-capacity information, parameter-to-sample ratios, learning curves, class-wise metrics, and a targeted class-weighting comparison are reported. Class-weighting was performed during the training phase only, but class-weighting did not yield highest performance for the tested Custom CNN configuration. of the chosen Custom CNN configuration for the observed dataset.
Abstract
INTRODUCTION: Computational classifiers can be benchmarked against public encoded splice-junction datasets, but the performance estimate will depend on the input representation, preprocessing pipeline, model set-up and evaluation design. METHODS: This study investigates the performance of 15 different Convolutional, Hybrid and Deep Learning architectures on a public encoded splice-junction dataset for 3-class classification. The results of the primary models were archived from one train/validation/held-out-test workflow and are presented as illustrative effects and not as statistically significant evidence of superiority. RESULTS: The highest held-out test accuracy (96.87%) was obtained with the Custom CNN from among the configurations that were saved. The MLP Mixer was the most highly accurate model during training (99.90%), but the model did not perform as well on the validation set (93.33%) or held-out test set (93.73%), suggesting some in-sample fitting. Model-capacity information, parameter-to-sample ratios, learning curves, class-wise metrics, and a targeted class-weighting comparison are reported. Class-weighting was performed during the training phase only, but class-weighting did not yield highest performance for the tested Custom CNN configuration. of the chosen Custom CNN configuration for the observed dataset. DISCUSSION: The conclusions are limited to the classification results that could be computed for the encoded benchmark dataset and the reported evaluation procedure. The results do not demonstrate a statistically significant superiority of the models in the sense of external generalization, clinical diagnostic validity, patient-based mutation detection, clinical utility or readiness for deployment. Leakage-free repeated evaluation, external datasets, stored sample predictions, statistically comparison of models' outputs, and clinically validated patient-level data would be needed for more general conclusions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data LeakageDiagnostics · 2026
- Homology aware benchmarking of deep learning models for CAZy enzyme family classificationDiscover Artificial Intelligence · 2026
- COOT-CNN: joint architecture and training-strategy optimization for binary colorectal histology patch classification.Scientific reports · 2026
- Comparative Analysis of CNN Architectures for High-Accuracy Subtype Classification of Renal Cell Carcinoma Using CECT.IEEE open journal of engineering in medicine and biology · 2026
- Classifying CRISPR-Cas9 Off-Target Cleavage Sites from GUIDE-seq Data: A Class-Imbalanced Machine Learning BenchmarkbioRxiv · 2026
- SynthraXCoreNet: An Interpretable, Well-Calibrated Six-CNN Ensemble for Dermoscopic Skin-Lesion ClassificationIEEE Access · 2025