Benchmarking Deep Learning Protocols in Dermoscopic Skin-Cancer Classification: Performance Sensitivity and the Limits of Grad-CAM in Auditing Data Leakage
Su-Ying Wen, Yuan-Mao Lin, Hsi-Chieh Lee
Key points
From the paper's conclusion- We establish a leakage-controlled benchmark for malignant-versus-benign dermoscopic classification, quantify how far evaluation choices move performance relative to architecture, and test whether attribution maps can reveal leakage.
Abstract
Background/Objectives: Published HAM10000 results are hard to compare because evaluation choices, notably the data split, are rarely controlled. We establish a leakage-controlled benchmark for malignant-versus-benign dermoscopic classification, quantify how far evaluation choices move performance relative to architecture, and test whether attribution maps can reveal leakage. Methods: Six ImageNet-pretrained convolutional neural networks and their ensembles were trained on HAM10000 (10,015 images) with a lesion-grouped split, three seeds, and validation-selected checkpoints and thresholds. The pipeline was repeated on an image-level split, ConvNeXt-Tiny was tested unchanged on ISIC 2020 (33,126 images), and eleven attribution methods were scored for faithfulness, localization and sensitivity to weight randomization. Results: ConvNeXt-Tiny reached an area under the receiver operating characteristic curve (AUC) of 0.925 ± 0.005 (sensitivity 85.3%, specificity 83.0%), and an eight-model ensemble 0.940 ± 0.001 with a precision-recall AUC of 0.832, above the only published lesion-grouped comparator (0.822), whose AUC it matches within one standard error. The four modern architectures were indistinguishable (all pairwise p ≥ 0.43), whereas an image-level split raised AUC by 0.027 and last-epoch evaluation lowered it by 0.018. On ISIC 2020, where only melanoma is labeled positive, AUC was 0.730 and sensitivity at the transferred threshold fell from 84.6% (76.5% for melanoma) to 42.5%. Attribution methods agreed weakly (mean rank correlation 0.16), faithfulness was unrelated to localization, and none exposed the leakage-trained model; a union of the three most faithful maps improved faithfulness (p = 0.003). Conclusions: Under leakage-controlled evaluation, an eight-model ensemble matches the best published result, but evaluation protocol moves performance more than architecture does and must always be reported. Explanation methods should be chosen by measured faithfulness and reported as a panel.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Reproducible and Explainable Deep Learning Framework for Dermoscopic Image Analysis in Skin Cancer.Journal of clinical medicine · 2026
- Interpretable Deep Learning in Dermoscopy: An XAI-Driven Ensemble for Skin Lesion DiagnosisIEEE Access · 2026
- SynthraXCoreNet: An Interpretable, Well-Calibrated Six-CNN Ensemble for Dermoscopic Skin-Lesion ClassificationIEEE Access · 2025
- Generalizable, imbalance-aware skin-lesion classification under a strict leak-free, cross-dataset protocolScientific Reports · 2026
- Interpretable Skin Cancer Identification Using a Hybrid Deep Learning and XAI Framework on HAM10000Bioengineering · 2026
- Skin Cancer Classification Using Explainable Artificial Intelligence With an Ensemble Model and Rigorous Leakage Free ValidationmedRxiv · 2026