Frontiers in artificial intelligenceOpen accessSegmentation

A severity-aware multi-task CNN-transformer framework for explainable diabetic foot ulcer triage and mobile deployment.

Abdullah, Muhammad Ateeb Ather, Zulaikha Fatima, José Luis Oropeza Rodríguez

Center for Computing Research, Instituto Politécnico Nacional, Mexico City, Mexico. · Faculty of Allied Health Sciences, Superior University, Lahore Campus, Lahore, Pakistan.

Key points

From the paper's conclusion
  • On the held-out test set, the framework achieved 95.5% accuracy (95% CI, 94.7-96.1) and a macro F1 score of 0.953, while mean five-fold cross-validation accuracy was 96.5% ± 0.3 percentage points. External ordinal severity estimation yielded a Spearman correlation of ρ = 0.91. In the clinician-audited cohort, weighted Cohen's κ for model-clinician severity agreement was 0.952. Model-assisted review was associated with a change in recorded management intent in 27.6% of cases, and 92.6% of generated explanations were rated as clinically useful. Full on-device inference, including gradient-weighted class activation mapping and concept-based explanation generation, required 322 ms per image on a Snapdragon 8 Gen 1 device.

Abstract

INTRODUCTION: Diabetic foot ulcer (DFU) image classification can support timely clinical triage; however, many existing systems provide limited severity granularity, rely on single-source image datasets, and predominantly use pixel-level explanation methods. This study developed a seven-class, severity-aware, multi-task artificial intelligence framework for interpretable DFU image analysis and smartphone-class deployment. METHODS: The framework combines domain-adaptive SimCLR pretraining, U-Net-based image refinement, EfficientNet-B0 feature extraction, a lightweight windowed transformer fusion block, and parallel classification and ordinal severity-regression heads. Four public data sources-DFUC 2020/2021, AZH, Medetec, and an IWGDF-aligned ordinal repository-were harmonized and deduplicated, yielding an analytical corpus of 24,925 original images. Evaluation included a 3,739-image held-out test set, five-fold stratified cross-validation, leave-one-source-out testing, an independent prospective clinician-audited cohort of 366 images, calibration and uncertainty analyses, concept-based interpretability assessment, and mobile-device profiling. RESULTS: On the held-out test set, the framework achieved 95.5% accuracy (95% CI, 94.7-96.1) and a macro F1 score of 0.953, while mean five-fold cross-validation accuracy was 96.5% ± 0.3 percentage points. External ordinal severity estimation yielded a Spearman correlation of ρ = 0.91. In the clinician-audited cohort, weighted Cohen's κ for model-clinician severity agreement was 0.952. Model-assisted review was associated with a change in recorded management intent in 27.6% of cases, and 92.6% of generated explanations were rated as clinically useful. Full on-device inference, including gradient-weighted class activation mapping and concept-based explanation generation, required 322 ms per image on a Snapdragon 8 Gen 1 device. DISCUSSION: The proposed framework demonstrates how multi-source representation learning, multi-task severity modeling, uncertainty assessment, concept-based interpretability, and efficient edge deployment can be integrated within a unified AI pipeline for DFU image analysis. The findings indicate high classification performance, strong ordinal severity agreement, clinically interpretable outputs, and technically feasible smartphone-class inference. Further multicenter prospective validation across diverse populations and acquisition conditions is required before translation into routine clinical decision-support settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers