Frontiers in Endocrinology

Hybrid deep learning frameworks for enhanced segmentation of diabetic foot ulcers in clinical images

Suresh Sankaranarayanan, Aditi Ghosh, Krishna Lodha, Sornalakshmi K., Sharmila Banu Sheik Imam, Abdul Rahaman Wahab Sait

Computational

Key points

From the paper's conclusion
  • We evaluated the models on 2,002 usable image–mask pairs from the DFUC2022 dataset, comprising 1,601 training and 401 held-out test images under an 80:20 image-level split.

Abstract

Introduction Diabetic foot ulcers (DFUs) require accurate segmentation and precise boundary delineation to support automated wound assessment and quantitative analysis. This study evaluates two hybrid CNN–Transformer architectures, LeViT–UNet++ and Swin-Lightweight UNet++, for automated DFU segmentation from clinical foot images. Methods Both architectures integrate hybrid feature extraction with UNet++-based segmentation to generate pixel-level binary masks for ulcer identification and delineation. We evaluated the models on 2,002 usable image–mask pairs from the DFUC2022 dataset, comprising 1,601 training and 401 held-out test images under an 80:20 image-level split. We assessed segmentation performance using the Dice similarity coefficient and Intersection over Union (IoU) across three repeated experimental runs. We also reported inference time for both architectures. Results LeViT–UNet++ achieved a mean Dice score of 0.7970 ± 0.0309 and IoU of 0.6636 ± 0.0419, outperforming Swin-Lightweight UNet++, which achieved 0.4938 ± 0.0258 and 0.3282 ± 0.0230, respectively. The reported inference times were 10 ms per image for LeViT–UNet++ and 15 ms per image for Swin-Lightweight UNet++, indicating superior segmentation performance and faster inference for LeViT–UNet++ under the evaluated configurations. Discussion The findings demonstrate the potential of LeViT–UNet++ for automated DFU segmentation and boundary delineation. The generated segmentation masks may support future wound-area quantification, morphological assessment, and longitudinal monitoring, although we did not independently evaluate these downstream applications. Because the architectures differed in design and training configurations, we cannot attribute the observed performance differences exclusively to their attention mechanisms. Further validation using patient-independent splits and external clinical datasets is necessary to establish robustness and clinical generalizability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers