A 266-nm multi-reflection laser curtain for airborne bacterial inactivation in a 20-m3 chamber and a single-pass duct testbed.
Chenjie Guo
Department of Medical Equipment Management, Shanghai Pudong New Area Hospital of Traditional Chinese Medicine, Pudong New Area, Shanghai, China.
Key points
From the paper's conclusion- The multi-reflection 266 nm laser-curtain achieved high inactivation in controlled room-scale and duct single-pass tests, supporting further engineering evaluation of this air-disinfection concept rather than immediate healthcare deployment.
Abstract
BACKGROUND: Airborne transmission remains a challenge for infection prevention and control in healthcare environments, motivating compact air-disinfection technologies. METHODS: A compact 266 nm multi-reflection laser-curtain module was developed, providing two effective curtain widths (96 mm and 200 mm). Aerosolised Staphylococcus albus (S. albus; a coagulase-negative staphylococcal bacterial surrogate) was tested in (i) a mixed-air 20 m3 enclosure for time-dependent inactivation and (ii) a duct-flow single-pass rig using three curtains in series with paired upstream-downstream sampling. Matched no-UV controls were used for baseline correction, with first-order kinetics used for room-scale analysis. RESULTS: In the 20 m3 enclosure, inactivation increased with operating time. The 96 mm curtain achieved ~66-69% at 5 min and exceeded 98% by 30 min, approaching ≥99.9% with extended operation. The 200 mm curtain exceeded 99.5% by 20 min and approached ≥99.99% at longer times, with a numerically higher apparent rate constant (0.190 vs. 0.127 min-1). In the duct-flow system, three curtains maintained ≥99.0% single-pass inactivation across 1.2-9.6 m/s. CONCLUSIONS: The multi-reflection 266 nm laser-curtain achieved high inactivation in controlled room-scale and duct single-pass tests, supporting further engineering evaluation of this air-disinfection concept rather than immediate healthcare deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In-Situ Disinfection of Hospital Privacy Curtains Using a Next-Generation Aerosolized Hydrogen Peroxide SystemmedRxiv · 2026
- Air disinfection effect of different disinfection methods in high-risk healthcare spaces.Photochemistry and photobiology · 2026
- A Laser-Based Rapid Method for the Targeted Inactivation of Escherichia coli and Saccharomyces cerevisiaeBioNanoScience · 2026
- Validated computational modeling to evaluate spatial inactivation of airborne pathogens by Far-UVC irradiation.Photochemistry and photobiology · 2026
- As a component of aseptic technique, Bunsen burners do not universally decrease deposition of microbe-containing particles.Microbiology spectrum · 2026
- Inactivation of Bacterial and Viral Bioaerosols by Lactoferricin B-Coated Filters Under Various Environmental ConditionsHygiene · 2026