Finite element analysis of transverse three-Kirschner-wire fixation for distal radial diametaphyseal junction fractures in children
Zhihong Wan, Hao Liang, Rui Ma, Jia Huang, Zhiyi Zhou, Xiaojun Chen
Key points
From the paper's conclusion- Using finite-element analysis (FEA), this study investigated the biomechanical performance of transverse three-Kirschner-wire fixation for pediatric distal radial diametaphyseal junction (DMP) fractures and compared it with conventional pinning techniques, so as to provide biomechanical evidence for further experimental and clinical application of this novel fixation strategy.
Abstract
Objective To establish an idealized three-dimensional finite-element model based on forearm computed tomography data from an 11-year-old child. Using finite-element analysis (FEA), this study investigated the biomechanical performance of transverse three-Kirschner-wire fixation for pediatric distal radial diametaphyseal junction (DMP) fractures and compared it with conventional pinning techniques, so as to provide biomechanical evidence for further experimental and clinical application of this novel fixation strategy. Materials and methods Forearm CT datasets from a healthy 11-year-old boy and 2.0-mm Kirschner-wire parameters were imported into dedicated software. A standardized DMP transverse fracture model was constructed. Four finite-element assemblies were generated: transverse three-Kirschner-wire group, transverse two-Kirschner-wire group, parallel Kirschner-wire group, and crossed Kirschner-wire group. Six loading scenarios (30 N flexion, 30 N extension, 30 N compression, 30 N distraction, 1 N·m internal rotation, and 1 N·m external rotation) were simulated in ANSYS Workbench. Fracture-fragment relative displacement and Kirschner-wire stress distribution were compared across groups. Results Under all six loading conditions, the transverse three-wire group yielded the smallest maximum fracture-fragment displacement (0.888 mm, 0.888 mm, 0.496 mm, 0.497 mm, 0.000257 mm, 0.000257 mm, respectively). Under flexion, extension, internal-rotation and external-rotation loads, the parallel-wire group produced the lowest peak Kirschner-wire stress (456.8 MPa, 457.31 MPa, 0.639 MPa, 0.639 MPa). Under compression and distraction, the transverse three-wire group exhibited the lowest wire stress (241.83 MPa and 241.45 MPa). Conclusion In this single-sample idealized FEA simulation, transverse three-Kirschner-wire fixation produced the smallest fracture-end displacement, indicating superior fracture stability. Although this configuration only achieved the lowest peak wire stress under compression and distraction, stress contour plots demonstrated multi-point, relatively homogeneous stress dispersion, with absolute stress values that showed only limited differences from those of the other groups, indicating satisfactory fixation strength within an acceptable range. These are purely computer-simulated findings and cannot substitute clinical outcomes. Further cadaveric biomechanical tests and large-scale clinical investigations are required for validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A comparative study of Kirschner wire intramedullary fixation versus bicortical fixation for metaphyseal-diaphyseal junction fractures of the pediatric distal radius.BMC musculoskeletal disorders · 2026
- Divergent K-wires in the sagittal plane have minimal impact on fixation stability and the resulting early clinical outcomes in patients with transverse patellar fractures.BMC musculoskeletal disorders · 2026
- Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.BMC musculoskeletal disorders · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Radiographic Outcomes of Open Reduction and Kirschner-Wire Fixation Versus Screw or Plate Fixation for Lisfranc Injuries: A Propensity Score-Weighted Comparative Study.Journal of clinical medicine · 2026
- Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fracturesArchives of Orthopaedic and Trauma Surgery · 2026