Positional variance of intraocular pressure in conscious New Zealand white rabbits.
Nicolas X Tovar, Levi H Smith, Claire Gould, Liam Clarke, Brenna Janowski, Hsin-Yi Weng, Shin Ae Park
Department of Veterinary Clinical Sciences, Purdue University College of Veterinary Medicine, West Lafayette, IN, United States. · Department of Comparative Pathobiology, Purdue University College of Veterinary Medicine, West Lafayette, IN, United States.
Key points
From the paper's conclusion- These findings should be considered in future ocular studies using NZW rabbits and may inform further investigations involving continuous IOP-monitoring devices.
Abstract
INTRODUCTION: Glaucoma is one of the leading causes of irreversible vision loss. It is a complex optic neuropathy, with elevated intraocular pressure (IOP) as one of the major risk factors. Recent studies are exploring new devices and technologies for continuous IOP measurement to better monitor glaucoma progression. Rapid and reliable methods for inducing alterations in IOP in laboratory animals may facilitate the development of these technologies. The purpose of this study was to investigate changes in IOP in conscious rabbits placed in different body positions and to assess whether IOP changed with increased duration in each position. METHODS: The IOP (mean ± SD mmHg) of twelve New Zealand White (NZW) rabbits, six males and six females, was measured at 1-minute intervals for 5 minutes in prone (19.8 ± 3.7), head-up (18.3 ± 2.7), head-down (22.5 ± 3.6), and supine (23.9 ± 3.8) positions. RESULTS: IOP differed significantly among all positions (p < 0.001). When IOP measurements obtained from minutes 1 to 5 were compared, no significant differences were observed within any position (p > 0.38). DISCUSSION: IOP in rabbits can be significantly altered by changing body position among prone, head-up, head-down, and supine positions. These findings should be considered in future ocular studies using NZW rabbits and may inform further investigations involving continuous IOP-monitoring devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-angle validation of the iFalcon V700 rebound tonometer against implantable pressure sensor in ex-vivo rabbit eyesScientific Reports · 2026
- Postural Intraocular Pressure Changes and the Trans-Lamina Cribrosa Pressure Difference: A Systematic Review and Meta-Analysis.Ophthalmology. Glaucoma · 2026
- Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious CatsVeterinary Ophthalmology · 2026
- Comprehensive Ophthalmic Evaluation of Clinically Normal Rhesus Monkeys ( Macaca mulatta ): Selected Ophthalmic Diagnostic Tests, Tear‐Film Biochemistry and Serum Correlations, Conjunctival Microbiota and Ophthalmic Artery HaemodynamicsVeterinary Medicine and Science · 2026
- Changing tonometers, changing intraocular pressure? Rethinking intraocular pressure interpretation in dogs.The Journal of small animal practice · 2026
- Ex Vivo Validation of the TONOVET Plus and TONOVET Pro in Cynomolgus Monkeys (Macaca fascicularis): Comparison of Canine and Lapine Calibration Modes.Veterinary ophthalmology · 2026