Dose history in real-time dose-guided multileaf collimator tracking
Shichao Zhang
Key points
From the paper's conclusion- Real-time dose-guided multileaf collimator tracking uses accumulated dose estimates to adapt subsequent irradiation during target motion.
Abstract
Real-time dose-guided multileaf collimator tracking uses accumulated dose estimates to adapt subsequent irradiation during target motion. This Mini Review examines when dose history may improve dose delivery beyond geometric or fluence-based tracking. Five representative studies are compared across single-target motion, differential multi-target motion, and anatomical deformation. Single-target simulations showed improved agreement between modeled and planned dose with dose optimization, whereas a phantom experiment on a magnetic resonance imaging–guided linear accelerator (MRI-linac) yielded numerically similar results for dose-guided and geometric tracking. In a selected dual-target geometry with overlapping beam projections, dose-guided tracking improved pooled measured dose agreement, with benefit dependent on the motion scenario. Deformation studies demonstrated the importance of tissue correspondence, but comparisons retaining dose history in both arms primarily tested motion representation. The available evidence suggests that history may be useful when accumulated dose errors alter aperture decisions and the remaining irradiation allows those errors to be corrected. Feedback on actual delivery and organ-at-risk objectives may help translate modeled gains into delivered-dose improvements. Comparisons that explicitly isolate accumulated-dose feedback, followed by independent dosimetric verification, are needed to establish where dose history provides an incremental advantage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Retrospective log-based quality assurance of real-time MLC adaptation on a helical tomotherapy platform.Journal of applied clinical medical physics · 2026
- MRI Guided Radiotherapy using Deformable Gel DosimetryJournal of Physics: Conference Series · 2026
- Configuration of a Monte Carlo-Based Secondary Plan Verification Tool: An Analytical Approach to User-Specific Parameter Tuning.Biomedical physics & engineering express · 2026
- Evaluation of GPU-accelerated Monte Carlo beam and agility MLC modeling in the Monaco treatment planning system.Journal of applied clinical medical physics · 2026
- Adaptive Radiotherapy: Principles, Technologies, Clinical Applications, and Future Directions — A Comprehensive ReviewInternational Journal of Drug Delivery Technology · 2026
- Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristicsJournal of Applied Clinical Medical Physics · 2026