Inter-subject receive-template substitution for quantitative brain water content mapping at 3 T: a leave-one-out evaluation.
Zaheer Abbas, Faizan Ullah, Sergo Gegechkori, Wieland A Worthoff, N Jon Shah
Institute of Neuroscience and Medicine 4, Medical Imaging Physics, Forschungszentrum Jülich, Jülich, Germany.
Key points
From the paper's conclusion- Primary outcomes were participant-level median quantitative water content (qWC) in white and gray matter; whole brain was secondary.
Abstract
INTRODUCTION: To evaluate a configuration-specific inter-subject receive template as an alternative to participant-specific receive referencing within the evaluated 3 T scanner configuration. METHODS: Datasets from twenty-five healthy subjects were analyzed using a strict leave-one-participant-out method. Each degree-3 template used the other 24 participants. Arm E used a participant-specific effective relative receive divisor; Arm T used the held-out template. Both arms underwent independent, identically defined residual calibration, including a local intercept (C0), its spatially regularized field (μ), and the mean-normalized form used downstream (μ). This was followed by ventricular-CSF calibration. Primary outcomes were participant-level median quantitative water content (qWC) in white and gray matter; whole brain was secondary. Paired bias, mean absolute error (MAE), Bland-Altman limits, Pearson r, and Lin concordance correlation coefficient (CCC) were calculated. RESULTS: Mean relative receive-template mismatch was 2.273% (standard deviation (SD), 0.568%; range, 1.431%-3.615%). Mean Arm T minus Arm E differences were -0.04 percentage units (p.u.; dimensionless water fraction relative to pure water = 100 p.u.) in white matter and -0.17 p.u. in gray matter; MAE was 0.17 and 0.22 p.u., and CCC was 0.991 and 0.989, respectively. Whole-brain bias was -0.12 p.u. (MAE, 0.19 p.u.; CCC, 0.993). Bland-Altman widths were below 1 p.u. Exploratory associations between global mismatch and qWC disagreement were weak; all 95% participant-bootstrap confidence intervals spanned zero. DISCUSSION: Under symmetric arm-specific calibration, the configuration-specific template produced qWC estimates in close agreement with the participant-specific explicit reference strategy. This internal matched-configuration result supports technical feasibility but does not establish formal equivalence, interchangeability, or external generalization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Noise-referenced multi-shell diffusion-weighted imaging for regional cerebrospinal fluid thermometrybioRxiv · 2026
- Quantitative proton density mapping with data-driven reception profile correction derived from macromolecular proton fraction.medRxiv : the preprint server for health sciences · 2026
- Optimizing myelin water imaging in multiple sclerosis.NeuroImage. Clinical · 2026
- Myelin water fraction mapping with voxelwise appraisal of solution ambiguity by globally optimized single and joint inversion of spin- and gradient-echo data.Magnetic resonance imaging · 2026
- Improved Myelin Water Fraction Estimation and Uncertainty Mapping in Multicomponent T2 Relaxometry via NNLS Bootstrap AggregationarXiv · 2026
- Separation of Water Components from Multi-Echo MRI Data Using Deep Learning-Assisted Subspace Modeling.IEEE transactions on medical imaging · 2026