NeuroImage. Clinical

Optimizing myelin water imaging in multiple sclerosis.

Ellis Donders, Guus H J Vorst, Pien M Schipper, Joost P A Kuijer, Eva M M Strijbis, Joep Killestein, Hugo Vrenken, Frederik Barkhof,

MS Center Amsterdam, Amsterdam UMC location Vrije Universiteit Amsterdam, Department of Radiology and Nuclear Medicine, De Boelelaan 1117, Amsterdam, the Netherlands; Amsterdam Neuroscience, Brain Imaging, Amsterdam, the Netherlands. Electronic address: e.donders@amsterdamumc.nl. · Amsterdam Leukodystrophy Centre, Department of Child Neurology, Emma Children's Hospital, and Amsterdam Neuroscience, Amsterdam University Medical Center, Vrije Universiteit, Amsterdam 1105, AZ, the Netherlands.

Key points

From the paper's conclusion
  • Multi-echo gradient-echo (MEGRE) sequences with Variable Flip Angles (VFA), combined with diffusion-weighted imaging (DWI), can generate robust, whole-brain myelin water fraction (MWF) maps more efficiently than conventional implementations.

Abstract

Myelin water imaging (MWI) allows in vivo quantification of myelin content using MRI. Multi-echo gradient-echo (MEGRE) sequences with Variable Flip Angles (VFA), combined with diffusion-weighted imaging (DWI), can generate robust, whole-brain myelin water fraction (MWF) maps more efficiently than conventional implementations. We evaluated how spatial resolution and number of flip angles affect MWI quality in a clinical research setting. Fifteen people with MS and ten healthy controls were scanned at 3 T (Siemens VIDA). MRI included multi-shell DWI and 3D-MEGRE acquired at 2.0 mm and 2.5 mm isotropic resolution. Twelve echoes were acquired at five flip angles. MWF was quantified based on a three-compartment T1, T2*, and DWI model, and determined in normal appearing white matter (NAWM), lesions and corpus callosum. Associations between MWF across resolutions and VFA schemes were assessed using Bland-Altman, ICC-C and ICC-AA. MWF was highest in corpus callosum (10.2 ± 1.1%), intermediate in NAWM (7.9 ± 0.7%), and lowest in lesions (4.9 ± 0.7%) (values for 2.0 mm and FA5). A FA4 MEGRE protocol showed comparable MWF values, while FA3 systematically overestimated MWF and showed greater variability, particularly in lesions. ICC-C between spatial resolutions was good to excellent (0.80-0.91), ICC-AA was moderate to good (0.66-0.81), indicating that the two resolutions should not be treated interchangeably. QC monitoring of fitting results is recommended to strengthen reliability of MWF results. MWI duration can be shortened with a FA4 MEGRE protocol. Resolution choice should be guided by study aims, as 2.0 mm and 2.5 mm were not fully interchangeable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers