3D confocal imaging reveals quantitative bias in cerebral microhemorrhage counts from standard histology
Danny F. Xie, Christian Crouzet, Wei Ling Lau, David H. Cribbs, Mark J. Fisher, Bernard Choi
Key points
From the paper's conclusion- We compared CMH counts from comprehensive three-dimensional imaging to those obtained from simulated standard two-dimensional histological sectioning.
Abstract
Standard histological quantification of cerebral microhemorrhages (CMH), the pathologic substrate of cerebral microbleeds, may systematically undercount lesion burden due to sparse tissue sampling. CMH are visualized using Prussian blue-stained 2D tissue sections. This method provides a snapshot of CMH lesions within a brain but does not capture comprehensive quantification across the entire brain. Tissue clearing combined with confocal microscopy can visualize intact CMH lesions in large tissue samples without tissue sectioning. We collected three-dimensional confocal images of optically-cleared, 1-mm-thick brain sections. We compared CMH counts from comprehensive three-dimensional imaging to those obtained from simulated standard two-dimensional histological sectioning. Sparse sampling (one 40-μm-thick section out of every six) resulted in the omission of 38% of individual CMH, disproportionately affecting smaller lesions. Increasing sectioning frequency to one in every 2–3 sections lowered the miss rate to 13%–20% but concurrently increased the likelihood of counting single lesions multiple times. These results demonstrate that tissue sampling frequency substantially affects CMH quantification. Our data suggest using 40-μm sections at a 1-every-4 frequency to provide a balance between omission of CMH, repeat counting of CMH, and workload. This recommendation may change for different study designs and/or experimental models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-dimensional quantification using contrast-enhanced micro-CT reveals regional heterogeneity of microhemorrhagic burden after focal cerebral ischemia in miceActa Neuropathologica Communications · 2026
- Neuronal quantification in the primary motor cortex of mouse brains fixed with solutions from human gross anatomy laboratoriesbioRxiv · 2026
- A Method for Eliminating Mixed Errors in Confocal Images by Integrating System Error Matrices with Low-Rank ApproximationPhotonics · 2026
- Quantitative three-dimensional absorption imaging of pigments and stains with brightfield microscopyBiomedical Optics Express · 2026
- Large-Field Mesoscopic Spinning-Disk Confocal Microscopy Enhances Quantitative Fidelity for In Vivo Cerebrovascular and Calcium Sensing.Analytical chemistry · 2026
- Stain-free three-dimensional organ imaging by serial optical coherence microscopy and tissue clearing: toward comprehensive histopathologynpj Imaging · 2026